COMBINATION RATINGS

ARI Ref. No.

Model Number

Indoor Model

Furnace Model

Capacity

EER

SEER

Phase

3047251

24ACB418A30

*CAP**2414A**+TDR

18000

11.50

14.00

1

3047259

24ACB418A30

CAP**1814A**

58CV(A,X)070---12

17600

12.50

15.00

1

3047252

24ACB418A30

CAP**1814A**

58PH*045---08

18000

12.75

15.25

1

3047258

24ACB418A30

CAP**1814A**+TDR

17800

11.20

13.50

1

3047260

24ACB418A30

CAP**2414A**

58CV(A,X)070---12

17900

13.00

15.50

1

3047253

24ACB418A30

CAP**2414A**

58PH*045---08

18200

13.00

15.50

1

3047263

24ACB418A30

CAP**2417A**

58CV(A,X)090---16

17900

13.00

15.50

1

3101813

24ACB418A30

CAP**2417A**

58MEB040---12

18000

13.20

16.00

1

3101814

24ACB418A30

CAP**2417A**

58MEB060---12

18000

13.20

16.00

1

3047262

24ACB418A30

CAP**2417A**

58MV(B,C)060---14

17900

13.00

15.50

1

3047261

24ACB418A30

CAP**2417A**+TDR

18000

11.50

14.00

1

3047277

24ACB418A30

CNPF*2418A**+TDR

18000

11.50

14.00

1

3047275

24ACB418A30

CNPH*2417A**

58CV(A,X)070---12

17900

13.00

15.50

1

3047276

24ACB418A30

CNPH*2417A**

58CV(A,X)090---16

17900

13.00

15.50

1

3101817

24ACB418A30

CNPH*2417A**

58MEB040---12

18000

13.00

15.75

1

3101818

24ACB418A30

CNPH*2417A**

58MEB060---12

18000

13.00

15.75

1

3047272

24ACB418A30

CNPH*2417A**

58MV(B,C)040---14

17900

13.00

15.50

1

3047273

24ACB418A30

CNPH*2417A**

58MV(B,C)060---14

17900

13.00

15.50

1

3047274

24ACB418A30

CNPH*2417A**

58MV(B,C)080---14

17900

13.00

15.50

1

3047256

24ACB418A30

CNPH*2417A**

58PH*045---08

18200

13.00

15.50

1

3047271

24ACB418A30

CNPH*2417A**+TDR

18000

11.50

14.00

1

3047265

24ACB418A30

CNPV*1814A**

58CV(A,X)070---12

17600

12.50

15.00

1

3047254

24ACB418A30

CNPV*1814A**

58PH*045---08

18000

12.75

15.25

1

3047264

24ACB418A30

CNPV*1814A**+TDR

17800

11.20

13.50

1

3047267

24ACB418A30

CNPV*2414A**

58CV(A,X)070---12

17900

13.00

15.50

1

3047255

24ACB418A30

CNPV*2414A**

58PH*045---08

18200

13.00

15.50

1

3047266

24ACB418A30

CNPV*2414A**+TDR

18000

11.50

14.00

1

3047270

24ACB418A30

CNPV*2417A**

58CV(A,X)090---16

17900

13.00

15.50

1

3101815

24ACB418A30

CNPV*2417A**

58MEB040---12

18000

13.00

15.75

1

3101816

24ACB418A30

CNPV*2417A**

58MEB060---12

18000

13.00

15.75

1

3047269

24ACB418A30

CNPV*2417A**

58MV(B,C)060---14

17900

13.00

15.50

1

3047268

24ACB418A30

CNPV*2417A**+TDR

18000

11.50

14.00

1

3047282

24ACB418A30

CSPH*2412A**

58CV(A,X)070---12

17900

13.00

15.50

1

3047283

24ACB418A30

CSPH*2412A**

58CV(A,X)090---16

17900

13.00

15.50

1

3101819

24ACB418A30

CSPH*2412A**

58MEB040---12

18000

13.00

15.75

1

3101820

24ACB418A30

CSPH*2412A**

58MEB060---12

18000

13.00

15.75

1

3047279

24ACB418A30

CSPH*2412A**

58MV(B,C)040---14

17900

13.00

15.50

1

3047280

24ACB418A30

CSPH*2412A**

58MV(B,C)060---14

17900

13.00

15.50

1

3047281

24ACB418A30

CSPH*2412A**

58MV(B,C)080---14

17900

13.00

15.50

1

3047257

24ACB418A30

CSPH*2412A**

58PH*045---08

18200

13.00

15.50

1

3047278

24ACB418A30

CSPH*2412A**+TDR

18000

12.00

14.00

1

3047288

24ACB418A30

FEUI

18200

13.20

16.00

1

3047289

24ACB418A30

FF1ENP018

17800

11.20

13.50

1

3047290

24ACB418A30

FF1ENP024

18000

11.20

13.50

1

3047291

24ACB418A30

FV4BNF002

18200

13.20

16.00

1

3047286

24ACB418A30

FX4CNF018

18000

13.00

15.50

1

3047287

24ACB418A30

FX4CNF024

18300

13.00

15.50

1

3047284

24ACB418A30

FY4ANF018

17800

11.20

13.50

1

3047285

24ACB418A30

FY4ANF024

17900

11.20

13.50

1

3047292

24ACB424A30

*CAP**2414A**+TDR

23200

11.70

14.00

1

3047301

24ACB424A30

CAP**2414A**

58CV(A,X)070---12

23000

13.00

15.50

1

3047293

24ACB424A30

CAP**2414A**

58PH*045---08

23200

12.75

15.25

1

3047304

24ACB424A30

CAP**2417A**

58CV(A,X)090---16

23000

13.00

15.50

1

3101821

24ACB424A30

CAP**2417A**

58MEB040---12

23200

13.00

15.75

1

3101822

24ACB424A30

CAP**2417A**

58MEB060---12

23200

13.00

15.75

1

3101823

24ACB424A30

CAP**2417A**

58MEB080---12

23200

13.00

15.75

1

3047303

24ACB424A30

CAP**2417A**

58MV(B,C)060---14

23000

13.00

15.50

1

3047302

24ACB424A30

CAP**2417A**+TDR

23200

11.70

14.00

1

3047306

24ACB424A30

CAP**3014A**

58CV(A,X)070---12

23200

13.00

15.50

1

3047294

24ACB424A30

CAP**3014A**

58PH*045---08

23400

13.00

15.50

1

3047305

24ACB424A30

CAP**3014A**+TDR

23400

12.00

14.00

1

3047309

24ACB424A30

CAP**3017A**

58CV(A,X)090---16

23200

13.20

16.00

1

3101824

24ACB424A30

CAP**3017A**

58MEB040---12

23800

13.20

16.00

1

3101825

24ACB424A30

CAP**3017A**

58MEB060---12

23800

13.20

16.00

1

3101826

24ACB424A30

CAP**3017A**

58MEB080---12

23800

13.20

16.00

1

3047308

24ACB424A30

CAP**3017A**

58MV(B,C)060---14

23200

13.00

15.50

1

3047307

24ACB424A30

CAP**3017A**+TDR

23400

12.00

14.00

1

3047344

24ACB424A30

CNPF*2418A**+TDR

23200

11.70

14.00

1

3047327

24ACB424A30

CNPH*2417A**

58CV(A,X)070---12

22800

12.50

15.50

1

3047328

24ACB424A30

CNPH*2417A**

58CV(A,X)090---16

23000

13.00

15.50

1

3047329

24ACB424A30

CNPH*2417A**

58CV(A,X)110---20

23000

12.50

15.50

1

3047330

24ACB424A30

CNPH*2417A**

58CV(A,X)135---22

23000

13.00

15.50

1

3047331

24ACB424A30

CNPH*2417A**

58CV(A,X)155---22

23000

13.00

15.50

1

3101833

24ACB424A30

CNPH*2417A**

58MEB040---12

23200

13.00

15.75

1

3101834

24ACB424A30

CNPH*2417A**

58MEB060---12

23200

13.00

15.75

1

3101835

24ACB424A30

CNPH*2417A**

58MEB080---12

23200

13.00

15.75

1

3047321

24ACB424A30

CNPH*2417A**

58MV(B,C)040---14

23000

12.50

15.50

1

3047322

24ACB424A30

CNPH*2417A**

58MV(B,C)060---14

23000

13.00

15.50

1

3047323

24ACB424A30

CNPH*2417A**

58MV(B,C)080---14

23000

12.50

15.50

1

3047324

24ACB424A30

CNPH*2417A**

58MV(B,C)080---20

22800

13.00

15.50

1

3047325

24ACB424A30

CNPH*2417A**

58MV(B,C)100---20

23000

13.00

15.50

1

3047326

24ACB424A30

CNPH*2417A**

58MV(B,C)120---20

22800

12.50

15.00

1

3047297

24ACB424A30

CNPH*2417A**

58PH*045---08

23000

12.75

15.25

1

3047320

24ACB424A30

CNPH*2417A**+TDR

23200

11.70

14.00

1

3047339

24ACB424A30

CNPH*3017A**

58CV(A,X)070---12

23200

13.00

15.50

1

3047340

24ACB424A30

CNPH*3017A**

58CV(A,X)090---16

23200

13.20

16.00

1

3047341

24ACB424A30

CNPH*3017A**

58CV(A,X)110---20

23200

13.00

15.50

1

3047342

24ACB424A30

CNPH*3017A**

58CV(A,X)135---22

23400

13.00

15.50

1

See notes on page 19

24ACB4

Summary of Contents for 24ACB4 Series

Page 1: ...TRY LEADING FEATURES BENEFITS Efficiency S 14 SEER 11 5 12 0 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 72 dBA S Compress...

Page 2: ...y Installation of this product should follow all manufacturing refrigerant charging and air flow instructions Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equ...

Page 3: ...60 96 m when outdoor unit is above indoor unit and up to 80 ft 24 38 m when the outdoor unit is below the indoor unit Refer to Accessory Usage Guideline below for required accessories See Longline Ap...

Page 4: ...TART X X X X X X X x Accessory See Accessory Usage Guideline for other accessories needed for low ambient cooling applications THERMOSTATS THERMOSTAT SUBBASE PKG DESCRIPTION TP PRH 01 Programmable The...

Page 5: ...imizes the chance of liquid slugging Usage Guideline Required in low ambient cooling applications Required in long line applications Suggested in all commercial applications 5 Cycle Protector The cycl...

Page 6: ...e superheat of the refrigerant gas leaving the evaporator Kit includes valve adapter tubes and external equalizer tube Hard shut off types are available NOTE When using a hard shut off TXV with single...

Page 7: ...cable tables of the NEC ANSI NFPA 70 Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2 Time Delay fuse FLA Full Load Amps LRA Locked Rot...

Page 8: ...8 DIMENSIONS ENGLISH 24ACB4...

Page 9: ...9 DIMENSIONS SI 24ACB4...

Page 10: ...ious examples Wall Wall Wall Wall 24 Service 6 152 4 mm 24 609 6 Service 24 609 6 Service 24 609 6 Service 24 609 6 Service 24 609 6 24 609 6 24 609 6 12 304 8 12 304 8 12 304 8 12 304 8 6 152 4 Note...

Page 11: ...0 FE4ANF002 UI 18200 13 20 16 00 1 3047289 24ACB418A30 FF1ENP018 17800 11 20 13 50 1 3047290 24ACB418A30 FF1ENP024 18000 11 20 13 50 1 3047291 24ACB418A30 FV4BNF002 18200 13 20 16 00 1 3047286 24ACB41...

Page 12: ...80 14 23200 13 00 15 50 1 3047349 24ACB424A30 CSPH 2412A 58MV B C 080 20 23000 13 00 15 50 1 3047350 24ACB424A30 CSPH 2412A 58MV B C 100 20 23200 13 00 15 50 1 3047351 24ACB424A30 CSPH 2412A 58MV B C...

Page 13: ...30 CNPH 3617A 58MV B C 080 20 28800 12 50 15 00 1 3047439 24ACB430A30 CNPH 3617A 58MV B C 100 20 28600 12 50 15 00 1 3047440 24ACB430A30 CNPH 3617A 58MV B C 120 20 28800 12 50 15 00 1 3047389 24ACB430...

Page 14: ...20 14 50 1 3047514 24ACB436A30 CAP 3617A TDR 35400 11 50 14 00 1 3047521 24ACB436A30 CAP 3621A 58CV A X 110 20 35200 13 00 15 00 1 3101885 24ACB436A30 CAP 3621A 58MEB100 20 35400 12 50 15 00 1 3047518...

Page 15: ...16 35800 13 00 15 25 1 3047507 24ACB436A30 CSPH 3612A 58PH 110 20 35800 13 00 15 25 1 3047548 24ACB436A30 CSPH 3612A TDR 35400 12 00 14 00 1 3047554 24ACB436A30 CSPH 4212A 58CV A X 070 12 35200 12 50...

Page 16: ...H 4821A 58MEB100 20 40000 12 50 15 00 1 3101935 24ACB442A30 CNPH 4821A 58MEB120 20 40000 12 50 15 00 1 3047646 24ACB442A30 CNPH 4821A 58MV B C 040 14 39500 12 20 14 50 1 3047647 24ACB442A30 CNPH 4821A...

Page 17: ...048 41500 13 00 15 00 1 3047682 24ACB442A30 FY4ANF042 40000 11 70 13 50 1 3047683 24ACB442A30 FY4ANF048 40500 11 70 13 50 1 3047748 24ACB448A30 CAP 6024A TDR 48000 11 50 14 00 1 3047777 24ACB448A30 CA...

Page 18: ...24ACB448A30 CSPH 6012A 58MV B C 080 20 46000 12 00 14 20 1 3047772 24ACB448A30 CSPH 6012A 58PH 070 16 47500 11 20 13 50 1 3047773 24ACB448A30 CSPH 6012A 58PH 090 16 48000 12 20 14 50 1 3047774 24ACB4...

Page 19: ...50 14 50 1 3047861 24ACB460A30 FX4CN B F 060 59500 12 00 14 00 1 3047860 24ACB460A30 FY4ANB060 59000 11 50 13 50 1 Tested combination EER Energy Efficiency Ratio SEER Seasonal Energy Efficiency Ratio...

Page 20: ...16 22 16 22 1 75 15 33 15 33 1 95 14 37 14 37 2 18 57 13 9 18 63 18 63 1 24 17 86 17 86 1 39 17 06 17 06 1 56 16 22 16 22 1 75 15 33 15 33 1 95 14 37 14 37 2 18 COOLING INDOOR MODEL CAPACITY POWER FU...

Page 21: ...X 090 16 CNPH 2417A 0 99 0 89 58CV A X 090 16 CNPH 3017A 1 00 0 89 58CV A X 090 16 CNPV 2417A 0 99 0 89 58CV A X 090 16 CNPV 3017A 1 00 0 89 58CV A X 090 16 COOLING INDOOR MODEL CAPACITY POWER FURNACE...

Page 22: ...0 93 58CV A X 090 16 CNPH 3617A 0 99 0 93 58CV A X 090 16 CNPV 3017A 0 99 0 93 58CV A X 090 16 COOLING INDOOR MODEL CAPACITY POWER FURNACE MODEL CNPV 3617A 0 99 0 93 58CV A X 090 16 CSPH 3012A 1 00 0...

Page 23: ...70 16 CAP 3617A 1 01 0 94 58PH 070 16 COOLING INDOOR MODEL CAPACITY POWER FURNACE MODEL CNPH 3017A 1 00 0 94 58PH 070 16 CNPH 3617A 1 00 0 94 58PH 070 16 CNPV 3017A 1 00 0 94 58PH 070 16 CNPV 3617A 1...

Page 24: ...16 CNPV 4217A 0 99 0 95 58CV A X 090 16 CAP 3621A 0 98 0 91 58CV A X 110 20 CAP 4221A 0 99 0 91 58CV A X 110 20 CNPV 3621A 0 98 0 94 58CV A X 110 20 COOLING INDOOR MODEL CAPACITY POWER FURNACE MODEL C...

Page 25: ...CAPACITY POWER FURNACE MODEL CAP 3621A 1 00 0 92 58PH 110 20 CAP 4221A 1 01 0 93 58PH 110 20 CNPH 3617A 0 99 0 95 58PH 110 20 CNPH 4221A 1 00 0 92 58PH 110 20 CNPV 3621A 0 99 0 95 58PH 110 20 CNPV 42...

Page 26: ...00 0 96 58CV A X 110 20 CNPH 4221A 0 99 0 97 58CV A X 110 20 CNPH 4821A 1 00 0 96 58CV A X 110 20 COOLING INDOOR MODEL CAPACITY POWER FURNACE MODEL CNPV 4221A 0 99 0 97 58CV A X 110 20 CNPV 4821A 1 00...

Page 27: ...1A 0 99 0 95 58PH 090 16 CAP 4821A 1 00 0 94 58PH 090 16 CNPH 4221A 0 99 0 95 58PH 090 16 CNPH 4821A 1 00 0 92 58PH 090 16 CNPV 4221A 0 99 0 95 58PH 090 16 CNPV 4821A 1 00 0 92 58PH 090 16 CSPH 4212A...

Page 28: ...5 0 91 58CV A X 090 16 CSPH 6012A 0 97 0 93 58CV A X 090 16 CAP 4821A 0 97 0 93 58CV A X 110 20 CAP 6021A 0 98 0 94 58CV A X 110 20 CNPV 4821A 0 96 0 92 58CV A X 110 20 CAP 4824A 0 98 0 94 58CV A X 13...

Page 29: ...NPV 6024A 0 97 0 97 58CV A X 110 20 CSPH 6012A 0 97 0 97 58CV A X 110 20 CAP 6024A 0 98 0 98 58CV A X 135 22 CNPH 6024A 0 97 0 97 58CV A X 135 22 CNPV 6024A 0 97 0 97 58CV A X 135 22 CSPH 6012A 0 97 0...

Page 30: ...2 78 TCG 33 40 31 70 30 00 28 30 26 50 24 70 22 90 20 90 SDT 72 60 81 80 90 90 100 10 109 30 118 60 127 80 137 10 KW 1 01 1 15 1 31 1 49 1 69 1 92 2 16 2 43 24ACB430A30 30 1 11 TCG 27 40 25 90 24 50 2...

Page 31: ...40 127 50 136 50 KW 2 14 2 43 2 76 3 12 3 53 3 97 4 45 4 97 45 7 22 TCG 60 10 57 00 53 90 50 70 47 30 43 80 40 10 36 20 SDT 74 60 83 50 92 50 101 50 110 50 119 50 128 50 137 40 KW 2 15 2 44 2 77 3 13...

Page 32: ...ricated bearings Shafts will be corrosion resistant Fan blades will be statically and dynamically balanced Condenser fan openings will be equipped with coated steel wire safety guards Compressor Compr...

Reviews: