Access Compressor Or Other Internal Cabinet
Components
NOTE:
Access to most of the components through the side panels of the
unit. The top will need to be removed to access the evaporator or
condenser coil. In some instances screws on the back of the unit (duct
side) will need to be accessed. If the unit is up against the structure, the
unit will have to be pulled away for servicing. Follow the procedures
below to access the different components:
1. Access to control box, compressor, reversing valve, metering
device, accumulator and liquid line drier.
a. Removal of the right front panel, opposite the duct flanges will
give access to the component above. (See
.)
2. Access to the indoor fan motor and electric heater
a. Removal of the right side (side with electric access), right back
panel to access components above. (See
.)
3. Access or removal of the condenser coil.
a. Removal of the top, the control/compressor panel, the front/left
side louver panel.
b. Screws from the compressor compartment and either the side of
the unit or below the condenser fan (depending on the shape of
coil) will need to be removed to remove condenser coil. (See
.)
4. Access or removal of the evaporator coil.
a. (024 to 036) The indoor evaporator coil is held in place by
screws located in the compressor compartment and behind the
return air duct. The 14” return collar must be removed to access
these screws.
b. (042 to 060) The indoor evaporator coil is held in place by
screws located in the compressor compartment and on the
rectangular duct flange. The rectangular duct flange does not
need to be removed but the left side screws will have to be
removed. (See
.)
A10160
Fig. 6 – Removal of Right Front Panel
A10159
Fig. 7 – Removal of Right Side Back Panel
A10161
Fig. 8 – Access of Condenser Coil
A10173
Fig. 9 – Location of Screws
HEATER
PLUG
WIRE
TIES
EVAPORATOR
CONDENSOR
COILS
SMALL, MEDIUM CHASSIS
MEDIUM, LARGE CHASSIS