PLUMBERS INSTALLATION INSTRUCTIONS - CONTROL BOX

IS1812(2)(02/19)

Sheet 2 of 2

To
Sensor
Cable

To tap outlet

From water supply

Control Box Components

Fig. 5

ELECTRONIC WALL MOUNTED OUTLET(REMOTE)

8 0

86

Fixing Holes

Control box

isolation valve

Step 2: Mounting Holes

Control 
Module

Fig. 4

Inlet

Outlet

Step 1: Remove Cover
            & Install Solenoid

Cover 

retaining

screw

Fig. 3

Control Box Mounting Instructions:

1)

2)

Remove control box cover: Using a phillips head screwdriver, remove

cover retaining screw. Apply a light force to the small button underneath

and gently lift off cover (Fig.3). With the cover removed you can see a

hexagonal brass nut. Remove this nut and replace it with enclosed solenoid.

Determine location & fasten control box to wall: Control box should be

located within 300mm from the wall outlet. Attach control box to wall using

4 supplied wall plugs & screws (Fig.4).

3)

Connect cables to controller: Remove split strain relief from box &

connect Power Supply cable to Control Module as shown in Fig. 2.

Then connect Control Module to Tap Sensor Cable and Tap Sensor

Cable to Solenoid.

Open the relief and pass Power Supply cable and Tap Sensor Cable

through. Wind up any excess Power Supply cable and store inside

the control box. 

Re-insert the strain relief and ensure that power, sensor, solenoid and

module cables are connected and secured (Fig.2).

4)

Connect power supply to a 240VAC, 10A GPO.

Ensure that supply of power has been isolated.

The power outlet should be located no more than 300mm from

the control box when using the standard cable. 

If a longer seperation is required, please use optional extension cable

(98454) to extend the distance up to a maximum of 2.2 meters.

Commissioning Procedure:

a) Turn on mains water supply & check for leaks 

     at both ends of the mains supply hose.

b) Open the control box isolation valve and 

     check for leaks at the remaining connections.

c)  Re-attach cover and fasten with retaining screw.

d) Power on the device at the GPO and allow the unit to

    complete the calibration sequence as follows:

       1) The indicator LED starts blinking.

       2) The indicator LED will turn off for 2 to 3 seconds performing

            calibration then a small amount of water will discharge. 

       3) The unit is now ready to operate.

e) Test operation by placing hands under the sensor (within 100mm from

    outlet of spout). Water should flow within 0.5 seconds.

    Remove hand and the water supply should stop within 2 seconds.

IMPORTANT: Please refer to AWARE Operation Manual (IS 1683) to configure

wireless communication and change the  device default settings.

6)

Flush the inlet and outlet lines before connecting to the Control Box.

Then connect inlet and outlet lines.

5)

Fig. 2

To Power Supply

To Sensor Cable

Solenoid (Red + Black)

To Solenoid (Green + Yellow)

To Module (Brown + White)

To Tap Sensor Cable

Split strain relief

Power Supply

WATER EFFICIENT - CONNECTED TAPWARE ENABLED BY AWARE

TM

Refer to side 1 of this instruction for wall outlet installation.

Static Inlet pressure range : 150 - 700 kPa.
New Regulation : 500 kPa maximum static pressure at
any outlet within a building. (Ref. AS/NZS 3500.1)