Caroma G Series Installation And Maintenance Manual Download Page 14

12

MAINTENANCE

If system chemical disinfection is practiced, chlorine can be used (calculated chlorine 

concentration of 50mg/l maximum in water per one hour dwell time) at service interval 

frequency.

FILTER CLEANING INSTRUCTIONS

These models are provided with a stainless steel filter preventing foreign particles to enter the lines. It is 

recommended to clean the filter every six (6) month. If the water flow has decreased, this may be because the 

filter is clogged. The filter can be cleaned as follows:
1.   a. Shut-off the water shut off valve.
 

b. Disconnect the water supply pipe from the adaptor and disassemble the filter.

 

c. Wash the filter under running water.

 

d. Reassemble the parts.

 

e. Restore the incoming water supply and make sure that there is no water leakage.

SOLENOID VALVE SERVICING

The

 

solenoid valve diaphragm requires periodical cleaning every six (6) month. 

Remove the diaphragm from the solenoid valve and examine it for dirt. in case it is dirty or clogged, wash it under 

running water and reassemble it. 

Do not attempt to dismantle the solenoid valve if you are unfamiliar with electronic solenoid valves.

CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT

 use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like. Use of any prohibited 

cleaning or maintenance products or substances could damage the surface of the outlet. For surface cleaning of 

outlet us 

ONLY

 soap and water, then wipe dry with clean cloth or towel. When cleaning bathroom tile, the outlets 

should be protected from any splattering of harsh cleansers.

Summary of Contents for G Series

Page 1: ...H A N D S F R E E WA L L M O U N T E D H A N D S F R E E WA L L M O U N T E D G SERIES ELECTRONIC OUTLET 205 INSTALLATION AND MAINTENANCE GUIDE INSTALLATION AND MAINTENANCE GUIDE ...

Page 2: ...ided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Caroma Industries LTD assumes no responsibility for errors or omissions in the information presented in this document In no event shall Caroma Industries LTD be liable for any special incidental indirect or c...

Page 3: ...nge Self adjusting sensor Manually adjustable with optional remote control Minimum sensor range 35mm Maximum sensor range 300mm Security time Flow will automatically stop after continuous running of 90 seconds Can be reduced with optional remote control Hot water temperature Max 70 C To prevent scalding ensure water is tempered to the appropriate temperature for the specific bathroom requirements ...

Page 4: ...screw 6 1 x Dual power input box with inlet nipple and filter 7 9V transformer 1 6 7 OPERATION This outlet features an IP67 dual power input box The product can be operated with a 9V battery or a 9V transformer In addition when used with a transformer the product contains an integrated battery backup for normal use during power supply failures ...

Page 5: ...tlet model with an infrared sensor pointing down is not intended to be used together with a washbasin of a reflective material such as stainless steel 3 If a washbasin strainer is straight below the outlet sensor use a strainer with a non reflective finish do not use a chrome plated one Min 300 mm Bottom of the washbasin PREPARATION FOR INSTALLATION Flush the water supply linesthoroughlybefore ins...

Page 6: ...hut off the water supply 2 Cut an adequate opening in the wall for the dimensions of the product base and the corrugated tube 3 Dismantle the outlet base 4 Drill four small holes for the product base support and drive the anchors in 80mm 80mm ...

Page 7: ...tlet base is perpendicular to the wall so the spout will be appropriately positioned for use IMPORTANT The outlet base should be installed so that the outside surface of the finished wall falls between the minimum and maximum lines marked at the base MIN MAX 6 Assemble the temporary protective outlet base cover 7 Make sure the corrugated tube will protrude out of the wall when tiling CORRUGATED TU...

Page 8: ...l rosette through the outlet base WALL ROSETTE 10 Carefully tie the flexible leads power and sensor with string to the water tube and feed it through the corrugated tubing FLEXIBLE TUBE 11 Connect the flexible tube to the dual power input box outlet 12 Fix the product spout by inserting the nipple into the outlet base and tighten the screw ...

Page 9: ... NOT CONNECTED PROPERLY ONLY THE GROOVES ARE VISIBLE CONNECTED PROPERLY 3 After you have connected the four contacts connector to the dual power input box wait 15 seconds in order to allow the system to set the ideal sensor range SECONDS ABOUT 15 As an indication that the self adjusting has taken place a LED in the sensor eye will flash continuously The solenoid valve will open and close for 1 sec...

Page 10: ...ose the function you want to adjust by pressing once on one of the function buttons After pressing once on a specific function button a quick flashing of the LED at the front of the sensor will occur At this stage you can change the setting by pressing the or the buttons every push will increase or decrease one level After finishing the adjustment turn the water supply back on DETECTION RANGE DELA...

Page 11: ...ding the remote control and move away from the sensor area The ideal sensor range for the specific location will be set automatically Once the self adjustment has taken place the solenoid valve will be opened and closed for 1 second as an indication that the ideal sensor range was set and the product is ready for use SECURITY TIME The Security time prevents continuous running of water due to refle...

Page 12: ...tivate it COMFORT FLUSH If your model includes a Comfort flush setting it can be activated by pressing the flush button When the button is pressed one blink of the LED in the sensor eye is perceived The pre programmed flush cycle will take place then The Comfort flush cannot be interrupted or deactivated by pressing any button until it is over TEMPORARY OFF FUNCTION This function is ideal to perfo...

Page 13: ...s in front of the sensor after the battery replacement was completed Carefully open the dual power input box using the Allen key provided Remove the old battery and replace it with a new 9V battery Lithium battery is recommended Close the box IMPORTANT These models were supplied with a self adjusting sensor The ideal sensor range for the specific location will be set automatically again after chan...

Page 14: ...rts e Restore the incoming water supply and make sure that there is no water leakage SOLENOID VALVE SERVICING The solenoid valve diaphragm requires periodical cleaning every six 6 month Remove the diaphragm from the solenoid valve and examine it for dirt in case it is dirty or clogged wash it under running water and reassemble it Do not attempt to dismantle the solenoid valve if you are unfamiliar...

Page 15: ...tomer service on 13 14 16 Please note warranty does not cover product damage caused by the following Incorrect installation inversions of supply pipes Pressures or temperatures exceeding recommended limits Improper manipulation tampering bad or lapsed maintenance Foreign bodies dirt or scale introduced by the water supply LIMITED WARRANTY ...

Page 16: ... sor s range Clean the orifice or replace diaphragm 2 The central orifice in the diaphragm is plugged or the diaphragm is torn Reduce the supply water pres sure 3 The water supply pressure is higher than 8 bar Shut off water supply and un screw one of the flexible pipes in order to reduce the pressure that blocks the product 4 The water supply pressure is under 8 bars and yet the pressure in the o...

Reviews: