Remote Control Operation

After the Remote Thermostat and Actuator have been linked, 
tested and installed by the installer, the Remote Thermostat is 
ready for use. In Remote Control Operation, the airflow is 
easily controlled by the user. The user presses the UP key to 
increase airflow or presses the DOWN key to decrease 
airflow. The airflow can be adjusted from 100% - the damper 
is fully open, to 0% - the damper is fully closed, or anywhere 
in between.

Indoors

Thermostat

o

F

Set To

Hold

AM

ed

Link

Tu

Menu

Linked

AM

Menu

If the Remote Thermostat is in Thermostat Mode, as shown in the 
image, change to Remote Control Mode.

Changing to Remote Control Mode

Press and hold the THERMOSTAT Key 
(shown in grey). The key will change to 
Remote as shown in the previous image 
and airflow will be displayed instead of 
temperature.

Tu

Make sure the Remote Thermostat is in 
Remote Control Mode as shown in the 
image. 

The display indicates Remote (shown in grey) 
and displays airflow instead of temperature 
(shown in grey).

%

Remote

Remote Control Mode

Remote Control - Airflow Displayed

%

Linked

Remote

AM

Tu

Menu

Press the UP/DOWN keys to change the 
damper position and airflow.

Linked

AM

Menu

Tu

%

Remote

Heat

Remote Control - Airflow & Indoor
Temperature Displayed

This Remote Control shows airflow and temperature displayed 
(shown in grey). See Option 7 to turn on temperature in the display. 

This Remote Control shows only airflow displayed (shown in grey).

Press the UP/DOWN keys to change the 
damper position and airflow.

2

Heat

Heat

LCD Touchscreen

The remote thermostat has been designed for long battery life and will “sleep” when not in use to 
maintain battery life. A moderate touch is recommended to “wake up” the remote thermostat. A 
moderate, steady touch is recommended to operate the keys. Pressing hard will not make the thermostat 
respond faster and may damage the LCD touchscreen. 

Important!

1.

1.

The damper can be adjusted from 100%, 
fully open, to 0%, fully closed, or a position 
in between.

1.

The damper can be adjusted from 100%, 
fully open, to 0%, fully closed, or a position 
in between.

Summary of Contents for Comfort Control

Page 1: ...d room temperature and whether the system is in heating or cooling A schedulecanbeprogrammedintothethermostattocontrolairflowfordaytimeandnighttime orfordaysoff Thermostat Mode Indoors Thermostat oF S...

Page 2: ...shown in grey and displays airflow instead of temperature shown in grey Remote Remote Control Mode Remote Control Airflow Displayed Linked Remote AM Tu Menu Press the UP DOWN keys to change the damper...

Page 3: ...the airflow to reach the setpoint temperature Indoors Thermostat oF Set To Hold AM ed Link Tu Menu In the Night Mode the thermostat sets the damper to the Nighttime position set in Option 5 The factor...

Page 4: ...re displayed The Remote Thermostat is shown in Thermostat Mode Schedule 1 Press the NEXT key to display the Day and Night schedule for each day 2 Or press ENTER if you have no more changes 1 2 3 4 5 D...

Page 5: ...removing and installing the Remote Thermostat on the sub base Table Top and Wall Mounts Table Foot Or install the sub base on an interior wall about 5 feet above the floor and out of sunlight using tw...

Page 6: ...d have been indicated as Installer Option oF Option 4 Setting discharge air temperature for detecting cooling call Factory Default 65 Menu Enter User User Installer Installer User Installer User Insta...

Page 7: ...in remote control mode The UP DOWN keys are used to adjust airflow This option sets the minimum airflow allowed and can be used to minimize damper noise Press and hold the MENU key to display Option 0...

Page 8: ...ting or cooling Remote Thermostat Actuator Doesn t Seem To Be Responding Ensure the actuator has power You may be able to observe the LED light on the actuator through the diffuser The LED light will...

Reviews: