G SERIES USER MANUAL
3.0 SOLAR PANEL AND CABINET INSTALLATION
Related functions within the Input/Output terminal block are grouped together:
INPT+
These are the hardware pushbutton or switch inputs that are referenced in the INPT
(Input) section of the user interface instructions. Multiple connections are made in
parallel. For information on configuring the behavior of the INPT terminals, see
INPT−
OUT1
Used for Applied Information time switches only. Pulses of voltage (relative to DC-)
indicate the system is operating with no detected fault.
OUT2
This terminal provides a 12 V (nominal, relative to DC-) signal whenever the
fixtures are activated and no faults are detected. See note below regarding OUT2 load
voltage and current considerations. For information on configuring, see
DC+
The DC+ / DC− terminals provide 12V
DC to power devices such as third-party time
switches (15V DC on AC-powered systems).
DC−
DC−
The DC− terminal is
bridged
to the DC− terminal above.
SWDC+
Wired to output of DC solid state relay for units with optional DC Relay Kit, see
Due to the variety of devices and fixtures that can be connected at the Input/Output terminal
block, the color assignments shown on the terminal block label may not be correct in all
cases. Please confirm correct connectivity and polarity for each fixture or device type.
The pushbutton input (INPT+, INPT-) is not a dry contact type. There is always 12-15VDC
present between these terminals, regardless of input configuration (NO, NC, or Button, see
). When connecting input devices other than standard traffic pushbuttons,
consideration must be given to electrical compatibility. Failure to isolate input signals
operating at different voltages or connection of devices that are designed to operate in a
different voltage range could result in poor performance or equipment damage. Please
contact Carmanah for additional support on connection of non-standard input devices.
The voltage available at the OUT2 terminal changes depending on the current flowing through
OUT2. See
in