background image

3 DISPLAY PANEL OPERATION

2008.9.19

9

ID

Address(001~066)

MENU

3.7

    ID ADDRESS

ID

 Enter the

ID

mode to set the ID ADDRESS.

3.8

    SPECIAL SETTINGS

SETTING

 Select

Upload

to upload the custom programs from the current MASTER unit to 

    the SLAVE units.

 In order to activate the upload function the password must be entered.

 Password is the same as the main access password.

 When uploading the MASTER and SLAVE units will be full on..

 If an error occurs when uploading the MASTER and/or SLAVE units will display 

    AMBER.

 On successful uploading of the custom programs the MASTER and SLAVE units 

    will display WHITE.

 In order to reset custom modes to default values select 

PESET Parameter

.

 Enter

ID ON/OFF

in order to allow/disallow ID address function from the 

   DMX512 controller.

SETTING

Upload
RESET Parameter

ID(ON/OFF)

Password

Password

ON
OFF

Sending

Resetting

End!

MODE

3.9

    A CTIVATE THE PASSWORD

KEYLOCK

 Enter the

KEYLOCK

mode to select whether the access password is on or off.

 In order to enter access password it is necessary to first press

SET

.

 Access password is

UP

+

DOWN

+

UP

+

DOWN

.

KEYLOCK

ON
OFF

MENU

CALIB

 Enter the 

CALIB

to select  white color of different color temperature.

 There are 8 pre-programmed White colors  can be edited

    by using 

White

&

Amber

 .

3.10

    WHITES SETTING

CALIB

WHITE 1
WHITE 2

WHITE 8

White
Amber

(0~255)
(0~255)

MODE

www.carlosmendoza.com.mx - (55) 56 72 85 69 - 72*15*18765

Summary of Contents for ambar

Page 1: ...LEDbloc USER MANUAL Blanco ambar www carlosmendoza com mx...

Page 2: ...WHITES SETTING 9 PART 1 PRODUCT GENERAL 1 1 1 PRODUCT INTRODUCTION 1 1 2 PRODUCT FEATURES 1 1 3 TECHNICAL SPECIFICATIONS 2 1 4 PHOTOMETRIC DATA 3 1 5 SAFETY WARNING 3 PART 2 INST ALLATION 4 2 1 MOUNT...

Page 3: ...rol Direct input of DMX512 signal allows the units to be controlled from any DMX512 controller This product can be operated as a single unit or in multiple units for large applications 1 2 PRODUCT FEA...

Page 4: ...65 protection rating 54pcs 42 x White 12 x Amber Weight LED Unit Output LED Cooling IP 1W Direct air convection 380 x 200 x 190mm 8Kg 100 240V 50 60Hz 80W 1 PRODUCT GENERAL 2 Environment Temperature 2...

Page 5: ...e wet ATTENTION This product left the place of manufacture in perfect condition In order to maintain this condition and for safe operation the user must always follow the instructions and safety warni...

Page 6: ...should also be used 220V 35 units may be connected in series 120V 15 units may be connected in series The LED MODULEcan be mountedat any angleand in any position It ispossible to furtheradjust the an...

Page 7: ...F from the Settings menu on the fixture Each DMX Address may be used as many times as required Any DMX address in the range from 001 to 512 may be used 2 3 2 DMX512 ADDRESSING WITH ID ADDRESS STUDIO 2...

Page 8: ...he user to collectively control the whole group of units at that DMX address by setting CH6 to 0 or to control each unit independently by first selecting the DMX address and then by using Ch6 to locat...

Page 9: ...through the main menu or return to the main menu 3 DISPLAY PANEL OPERATION 2008 9 19 SET UP DOWN MODE MODE 3 DISPLAY PANEL OPERATION 7 3 2 MENU MODE White Amber Strobe STATIC COLOR 0 255 0 255 Address...

Page 10: ...the DMX mode to set the DMX ADDRESS RUN MODE Enter the RUN MODE mode to set working mode DMX mode is for using the DMX512 controller to control the fixtures SLAVE mode is for Master Slave operation N...

Page 11: ...isplay WHITE In order to reset custom modes to default values select PESET Parameter Enter ID ON OFF in order to allow disallow ID address function from the DMX512 controller SETTING Upload RESET Para...

Page 12: ...It is possible to have the same DMX address or independent addresses for each fixture 4 2 CHANNEL ASSIGNMENT 10 4 USING A DMX512 CONTROLLER 2008 9 19 4 USING A DMX512 CONTROLLER WA 1 2 0 255 CHANNEL...

Page 13: ...4 3400K WHITE 5 4200K WHITE 6 4900K WHITE 7 5600K WHITE 8 5900K DIFFERENT WHITES NO FUNCTION 0 9 10 255 1 20Hz STROBE 5 ID ADDRESS ID1 ID66 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 ID9 ID10 ID11 ID12 ID13 0 9...

Page 14: ...mum CH2 and CH3 can be combined together to create whites with different color temperature STROBE CH 5 controls the strobe of CH1 to CH4 CH5 has priority over CH2 CH3 CH4 DIFFERENT WHITES Ch4 allow us...

Page 15: ...uttons damaged 2 Main PCB damaged 1 Replace buttons 2 Replace Main PCB 1 Signal Cable error 2 Signal conncetion error 3 The inputsignal IC damaged4 DMX address error Display normal but no response fro...