background image

5

Fig. 2 - Functional circuit diagram of 

ND12DCG

relay

TERMINAL

FUNCTION / CONNECTION

A1

+24 VDC or AC supply

A2

GND or AC supply

S11, S12, S22

First input botton

(S1)

S21, S12, S22

Second input botton

(S2)

Y1-Y2

Feedback control loop

34

PNP aux output

(collector of a PNP transistor with emit-

ter connected internally to VCC)

13-14

First safety output (NO)

23-24

Second safety output (NO)

31-32

Relay auxiliary output (NC)

Summary of Contents for ND12DCG

Page 1: ...User Manual User Manual SAFETY MODULE SAFETY MODULE ND12D CG ND12D CG...

Page 2: ...G AND OPENING 6 5 ELECTRONIC CONNECTION 6 5 1 Power supply 6 5 2 Close the feedback control loop and the input circuit 6 5 3 PNP auxiliary output 7 6 MAINTENANCE AND REPAIR 8 7 FAULT DIAGNOSIS 8 8 WIR...

Page 3: ...y paid attention to Nonobservance leads to serious injuries or damage to property IMPORTANT This word is placed in front of text which contains important information ACTIVITY This word is placed in fr...

Page 4: ...S12 S21 and S22 have to be wired up to the two hand control device as shown in the connection diagrams of this user s manual 3 3 Function The unit is enabled to start when the two switches S1 S2 are...

Page 5: ...ly A2 GND or AC supply S11 S12 S22 First input botton S1 S21 S12 S22 Second input botton S2 Y1 Y2 Feedback control loop 34 PNP aux output collector of a PNP transistor with emit ter connected internal...

Page 6: ...IN Rail mounting Carry out the wire appropriate to the use of the unit according to the technical data of this user s manual 5 ELECTRONIC CONNECTION 5 1 Power supply Connect the power supply to A1 and...

Page 7: ...ct to the 34 terminal an external resistive load with R 2400 Ohm see fig 3 Connect the ground of the PNP external circuit to A2 terminal if the safety relay is powered with 24 Vdc supply S12 internal...

Page 8: ...and the rated power supply is applied the device is ready for new operations Faulty contact condition In the event of welded contacts further activation is not possible following the opening of the i...

Page 9: ...ion 0 14 2 5 mm2 Rigid Wire 0 14 2 5 mm2 Flexible Wire Max Conductor Length input circuit cross section 1 5 mm2 4x150 m 55 C Max capacity of input cables 150 nF km CONTACTS DATA VALUES Safety Contacts...

Page 10: ...nal type DIN VDE 0470 Part 1 IP 20 Housing type DIN VDE 0470 Part 1 IP 40 Shock resistance DIN VDE 0160 5g 33 Hz CONTACTS DATA VALUES Mechanical lifetime 107 cycles Electrical lifetime 105 cycles 2A 2...

Page 11: ...11...

Page 12: ...12 CARLO GAVAZZI reserves the right to make improvements or changes without prior notice 8021639 MOD ND12DCG...

Reviews: