background image

23

ENGLISH

22

ENGLISH

 if the time base is, for instance, three times the period being measured

(see figure below), the updating of the display is made at the end of the
time base (end gate time) as average calculation of the measured
periods P=(P1+P2+Pn)/n

F7 : A, frequency (speed) clockwise and counter clockwise rotation
sensing mode.

This measuring capability is ideal for monitoring the relative speed of
shafts, conveyor belts and other moving machinery taking into account
the rotation mode, showing the reverse speed by means of a " - " sign.
The rotation sensing is detected by means of a phase difference,
measured using the two input channels available as standard in the
instrument. If we assume that the channel A is the main channel ( see
figure  on the next page), the channel B is used to detect if a signal
arrives "after" (phase displacement) the signal of the main channel
(begin gate time) meaning "clockwise" rotation or "before" meaning

mixture deviation that is connected to the quality result of the mixture
itself.

F6 : 1/A, period or average period mode

The instrument measures the frequency of input A or input B and
executes the following calculation: display=1/(Fa/Pu.1*PS.1). The time
period is directly connected to the time base that has been programmed
in the instrument (for low frequencies or long time periods):

 if the time base is in the range of the period being measured (see figure

below), the   updating of the display is as fast as possible and any period
changing is  updated immediately on the display;

Summary of Contents for MDI 40 TF - CONFIGURATION SOFTWARE

Page 1: ......

Page 2: ...V MDM Digital Meter al1 al2 RPM F S...

Page 3: ...Installation 7 Preliminary Operations 12 Front Panel Description 13 Operating mode 15 Important We suggest you keep the original packing for a further shipping of the instrument In order to guarantee...

Page 4: ...period measurement 20 s to 10s INPUT TYPE DC NPN pins 6 to 7 ON 2VDC OFF Open collector leakage current 1mA DC PNP pins 6 to 7 ON 10VDC OFF Open collector leakage current 1mA CARLO GAVAZZI Instrument...

Page 5: ...mic data reading only measurement valley data peak data alarm status Static data reading writing all programming data reset of peak and valley data reset of alarm set points with latch DC NAMUR ON 1mA...

Page 6: ...0Hz standard 200mAT protection fuse 115 VAC 15 10 50 60Hz on request 200mAT protection fuse 48 VAC 15 10 50 60 Hz on request 630mAT protection fuse 24 VAC 15 10 50 60 Hz on request 630mAT protection f...

Page 7: ...unting Insert the instrument into the panel and fasten it by fixing the two lateral brackets 1 supplied with the instrument to the appropriate location 2 and subsequently locking them by means of the...

Page 8: ...ck up up to 100VAC AC signals up to 500VAC Double input signal from 2 capacitive or inductive switches type NPN or PNP 3 wires NOTE when using a NPN or PNP in put the terminals 6 and 7 must be jumpere...

Page 9: ...he terminals 3 and 4 only free of voltage contact The voltage signals must be connected as follows 500V channel A to the terminals 1 and 5 channel B to the terminals 3 and 5 100V channel A to the term...

Page 10: ...nds the instruments software revision for example r 0 Displaying control and diagnostics The instrument shows continuously the value of the input variable as defined in the programming phase Displays...

Page 11: ...ommands used in the programming phase See the chapter Front panel description for information regarding the use of the key pad and the relevant main functions The value shown on the display is continu...

Page 12: ...ion display Fa Pu 1 PS 1 Fb HOLD Input Input A Display HOLD Input Input A B Display Glossary of displayed symbol PAS protection key programmable from 0 to 255 InP input range selection menu r1 from 0...

Page 13: ...nts the difference between the input channels and can be used when the speed difference between two conveyor belts has to be as low as possible without considering the reference speed of the first con...

Page 14: ...andard in the instrument If we assume that the channel A is the main channel see figure on the next page the channel B is used to detect if a signal arrives after phase displacement the signal of the...

Page 15: ...re Pu 1 number of pulses per revolution of the sensor proximity switch con nected to channel A Programmable value 1 Pu 1 9999 PS 1 Prescaler channel A stated in the following way A1 10 b1 A1 1 A1 9999...

Page 16: ...ent can measureanddisplay min frequency Hz 60 pulsesperrevolution that takes in our case 0 001 60 1 0 06 RPM t bA to select the proper time base in order to exploit the maximum performanceoftheinstrum...

Page 17: ...om 100 to 600 for the second one we can calculate the time period corre sponding to the minimum speed that is given by 60 min speed RPM pulses per revolution that makes in our case 60 100 4 sec theref...

Page 18: ...oose the F2 function SCA Pu 1 the number of pulses per revolution of channel A is in our case 4 therefore Pu 1 becomes 4 PS 1 the prescaler of channel A formed by the two sub param eters A1 mantissa a...

Page 19: ...larm d do down alarm with disabling at power on uP L up alarm with latch the alarm Where d diameter of the circumference n number of pulses per revolution dSY display parameter programming menu d P de...

Page 20: ...ontact is modified by means of an inside selectable solder jumper can be reset only if the F key will be held down for at least 2 seconds do L down alarm with latch the alarm can be reset only if the...

Page 21: ...that in our example corresponds to 20 FiL filter parameter programming menu This function allows you to stabilize the instruments digital display in order to obtain steady readings and better con tro...

Page 22: ...10 100 1V 10 10 therefore enter 10 00 Example maximum measured value 800 that must correspond to a retransmitted signal of 18mA Hi A 100 mA that in our example corresponds to 20 100 18mA 20 90 theref...

Page 23: ...back to the main menu the selection or programming modification will not be saved if the key has not been previously pressed YES NO In the menus press the key in order to exit from the programming ph...