WA R N I N G
!
When a kV setpoint button is pressed, the light above the
button will light and the kV display will show the present
voltage for that setpoint. This indicates the unit is set to
spray at that setpoint. To adjust the kV for the present
setpoint, press the + or - setpoint adjust buttons.
When the + or - setpoint adjust buttons are held in longer
than 1 second, the kV display will begin incrementing or
decrementing in units of 5 instead of 1.
DO NOT
turn the applicator off using the applica-
tor button in place of interlocking with a solvent sup-
ply for flushing. The applicator must be interlocked
with solvent supply such that when the solvent is on
to flush the applicator, there is no kV at the applicator.
Figure 6: Changing Setpoint
Changing the Setpoint at the Applicator
To change the setpoint at the applicator, the applicator
must NOT be triggered. By pushing the kV button on the
rear cover of the applicator, the setpoint will change. If
there are 2 green lights lit, setpoint 1 is active. If 2 green
lights and 2 yellow lights are lit, setpoint 2 is active. If
all lights are lit (2 green lights, 2 yellow lights, and 2 red
lights) setpoint 3 is active.
kV to the applicator can be turned off by pressing the ap-
plicator kV button in for 2-3 seconds. This can be done
whether the applicator is triggered or not and is useful if the
kV needs to be turned off for spraying into recessed areas.
When the kV is disabled in this manner, the kV meter will
read zero, OFF will be displayed in the microamp meter and
all kV setpoint indicator lights will be disabled. Pressing
the kV button in for another 2-3 seconds turns the kV to
the applicator back on.
Figure 7: View of Rear Cover
LOCKOUTS
There are lockouts that may be done at the PC board (see
Figure 8). These lockouts may be used individually or in
combination as required. If the jumpers are disconnected,
the original functions are re-enabled. After changing any
jumpers, the AC power must be cycled for the new setting
to take affect.
Figure 8: Lockout Jumper Location
AH-06-01-R17 (08/2019)
31 / 79
www.carlisleft.com