Figure 35: Trigger Shelf Removal
Figure 36: Trigger Stop Removal
8. Remove the trigger stop by turning the knob of the
stop counter-clockwise until the thread of the stop is
completely disengaged.
1
Finger Shelf Set Screw
2
Finger Shelf (pushed down)
Reassembly
(Refer to Figures 31-38)
1. Screw the trigger stop into the handle in a clockwise
direction.
2. Push the finger shelf up on the dovetail pad on the
handle to the desired height, insert the set screw and
tighten with a 3/32" Allen wrench.
3. Insert the fluid bracket over the air fitting, then install
the o-ring over the air fitting. Tighten the air fitting in a
clockwise direction.
Figure 37: Hook Insertion Into Handle
Figure 34: Fluid Bracket Removal
6. Remove the air inlet fitting and the fluid bracket from
the base of the applicator.
1
Fluid Bracket
2
Air Inlet Solvent Proof O-Ring
3
Air Inlet Fitting
7. Remove the trigger shelf by removing the set screw with
a 3/32" Allen wrench. Push down on the shelf to remove.
3
2
1
2
1
Description
Item #
FULL BRACKET REMOVAL
Description
Item #
TRIGGER SHELF REMOVAL
1
Trigger Stop Assembly
Description
Item #
TRIGGER STOP ASSEMBLY
1
AH-06-01-R17 (08/2019)