Spectra series
Error correction
1108 Service
instructions 53
Printhead temperature is too
high.
Defective printhead sensing
device.
Reduce contrast.
Change printhead.
With cut an error occurred.
Paper jam.
Check layout run.
Check cutter run.
Entered data do not correspond
to the characters allowed from
the application identifier.
Check code data.
Selected application identifier is
not available in the EAN 128.
Check code data.
F Missing HIBC system sign.
Missing primary code.
Check definition of HIBC code.
Real Time Clock function is
selected but the battery is
empty.
Defective RTC.
Change battery.
Change RTC component.
Interrupted connection CPU -
memory card.
Defective memory card
interface.
Check connection CPU -
memory card interface.
Check memory card interface.
No print memory found.
Check memory assembly on
CPU.
At start of a print order the
printhead is open.
Close the printhead and start
print order anew.
BCD error
Invalid format for the calculation
of Euro variable.
Check entered format.
BCD error
Invalid format for the calculation
of Euro variable.
Check entered format.
BCD error
Invalid format for the calculation
of Euro variable.
Check entered format.
Flash component error.
Run a software update.
Change CPU.