Installation and Initial Operation
Dynacode II IP
34
Operating Manual
03.21
7.1 Install the Print Mechanics at Machines
NOTICE!
With the open printing unit (due to construction) the requirements
of EN 62368-1 regarding fire protection casing are not fulfilled.
These must be ensured by the installation into the end device.
At the bottom of the mounting frame are two M8 threads that can be
used for the attachment at the machine. Additionally multi-functional
connecting parts are supplied.
Please observe the following conditions:
•
The maximum thread engagement of the M8 threads is 10 mm.
•
The print mechanics has to be installed with a distance from
printhead to brake stator of 2
… 3 mm (see illustration).
NOTICE!
A distance of 2 mm is recommended.
A smaller distance is not possible due to the sealing strip
at the bottom of the print mechanics, otherwise the
counter-pressure plate or pressure roller can touch the
print mechanics
•
The best print results can be received if the silicon of the pressure
roll consists of a hardness of approx. 40°
… 50 ° Shore A and/or
the elastometer of the counter-pressure plate shows a hardness
of approx. 60 ±
5 Shore A (average value of roughness Ra ≥ 3,2
mm).
•
The pressure roll/counter-pressure plate has to be installed
parallel to the linear movement of print unit and the focal line of
printhead. Discrepancies to the focal line and cavities in the print
surface can lead to an inferior print quality at these positions.
Figure 12
In case the machine is used without mounting frame, then the print
module is to be fixed from the top with four M6 screws.
The maximum thread engagement of the M6 threads is 6 mm.
(position of printhead see illustration)
Installation with
mounting frame
Installation without
mounting frame
Summary of Contents for Dynacode II IP107
Page 1: ...DYNACODE II IP Ingress Protection Version Operating Manual...
Page 6: ...Table of Contents Dynacode II IP 6 Operating Manual 03 21...
Page 10: ...Introduction Dynacode II IP 10 Operating Manual 03 21...
Page 16: ...Intermittent Mode Dynacode II IP 16 Operating Manual 03 21...
Page 20: ...Operating Conditions Dynacode II IP 20 Operating Manual 03 21...
Page 46: ...Load Transfer Ribbon Cassette Dynacode II IP 46 Operating Manual 03 21...
Page 124: ...Touch Screen Display Dynacode II IP 124 Operating Manual 03 21...
Page 132: ...Maintenance and Cleaning Dynacode II IP 132 Operating Manual 03 21...
Page 138: ...Signal Diagrams Dynacode II IP 138 Operating Manual 03 21...
Page 160: ...Additional Information Dynacode II IP 160 Operating Manual 03 21...
Page 162: ...Environmentally Friendly Disposal Dynacode II IP 162 Operating Manual 03 21...
Page 167: ......