12.5 Angle Adjustment (Intermittent Mode)
Figure 26
The installation angle of the printhead is default 26° to the print
surface. However, manufacturing tolerances of printhead and
mechanics can require another angle.
CAUTION!
Damage of printhead by unequal use!
Higher wastage of ribbon by faster ripping.
Only change the factory settings in exceptional cases.
1. Loosen slightly two Allen head screws (A).
2. Move the adjusting part (B) to adjust the angle between the
printhead and the printhead support.
move downwards = decrease angle
move upwards = increase angle
3. Tighten again the Allen head screws (A).
4. Start a print order with approx. three layouts to check the correct
unwrinkled ribbon run.
NOTICE!
The slots (C) serve for position control. Pay attention to a
parallel adjustment.
Summary of Contents for Dynacode II IP107
Page 1: ...DYNACODE II IP Ingress Protection Version Operating Manual...
Page 6: ...Table of Contents Dynacode II IP 6 Operating Manual 03 21...
Page 10: ...Introduction Dynacode II IP 10 Operating Manual 03 21...
Page 16: ...Intermittent Mode Dynacode II IP 16 Operating Manual 03 21...
Page 20: ...Operating Conditions Dynacode II IP 20 Operating Manual 03 21...
Page 46: ...Load Transfer Ribbon Cassette Dynacode II IP 46 Operating Manual 03 21...
Page 124: ...Touch Screen Display Dynacode II IP 124 Operating Manual 03 21...
Page 132: ...Maintenance and Cleaning Dynacode II IP 132 Operating Manual 03 21...
Page 138: ...Signal Diagrams Dynacode II IP 138 Operating Manual 03 21...
Page 160: ...Additional Information Dynacode II IP 160 Operating Manual 03 21...
Page 162: ...Environmentally Friendly Disposal Dynacode II IP 162 Operating Manual 03 21...
Page 167: ......