![Carinci evolution User Manual Download Page 22](http://html1.mh-extra.com/html/carinci/evolution/evolution_user-manual_2558158022.webp)
22
1 2 3 4 5 6 7
Fig. 1 External appearance and power linkage diagram
INPUTS
PROBE
Thermo fireplace probe : Temperature range 0 - 100 ° C
OUTPUTS
PUMP
System pump
230 Vac power supply
clips
3(N) - 4 (F
on)
VALVE
valve
230 Vac power supply
Clips
5(N) - 6 (F
OFF
) - 7 (F
ON
)
RECOMMENDED VALUES SETTING ON THERMOSTAT
Min
Max
Thermostat HEATING PUMP
53 °C
57 °C
Thermostat SANITARY WATER VALVE
40 °C
45 °C
MAIN Menu
By pressing and holding for about 5 secs. P1 button (MENU) it is possible to scroll set thermostats values signalled by the flashing of the respective
LED associated.
For editing:
Navigate to the value of the thermostat to modify;
Use the buttons P3 (+) and P2 (-) to increase/decrease the value;
To save changes, wait about 5 secs. or scroll through the values with the P1 button (MENU)
MAIN Menu Parameters
Symbol
Min
Factory
Max
Installed values
Thermostat PUMP 1
[°C]
A 07
20
50
85
Thermostat VALVE
[°C]
A 05
20
42
85
INSTALLER Menu
The access to this menu is LIMITED TO TECHNICIANS OR TRAINED PERSONNEL, since some parameters, if modified, can make the product no
longer suitable for the application in use.
To access the menu, press simultaneously
P1(MENU) P4 (ON/OFF)
buttons for about 5 seconds;
To scroll through the parameter labels use
P3 (+) and P2 (-)
buttons;
To display the parameter value, press
P1(MENU)
button
;
To change the value press
P3 (+) and P2 (-)
buttons and
P1(MENU) P4 (ON/OFF)
buttons simultaneously for about 5 seconds;
To redisplay the list of parameters and store press
P1(MENU)
button;
To exit and save wait approximately 5 seconds.
INSTALLER Menu Parameters
Symbol
Min
Factory
Max
Installed values
Activation thermostat ALARM function
[°C]
A 01
85
90
99
SAFETY thermostat
[°C]
A 02
20
85
90
ANTIFREEZE Activation thermostat [ICE]
[°C]
A 03
4
6
8
Hysteresis thermostat PUMP
[°C]
A 04
1
2
5
ANTI-LOCK timer
[h]
t 01
1
168
999
ANTI LOCK pump activation time
[sec]
t 02
0
20
99
6.20 ELECTRONIC CONTROL UNIT OF THE THERMO FIREPLACE CARINCI