LB-05053-03-GB
Pag. 15
03-04-13
PARAMETERS PROGRAMMING FOR THE MACHINE WITHOUT DISPLAY ( E1-P1/2 )
1) How to adjust boiler pressure:
To adjust the boiler working pressure ( 0.9 – 1.5 Bars ) turn the trimmer ( see pic. ) clockwise to increase the pressure and anti-
clockwise to decrease it.
The working pressure is displayed on the pressure gauge (see drawing A page 7 ) when the machine reaches the working temperature.
2) Pre infusion keys N°1 and N°2 (only for E1 version)
To enable or disable the pre infusion for the drink keys N° 1 e N°2, follow this procedure:
1.
Switch off the machine through the main switch ( I.G. ).
2.
Switch on the machine through the main switch, keeping pressed at the same time the key N°1 and n°2 till the key led
lights on , at this point the machine is ready for use.
3) Water filter Enablig / Disabling (only for E1 version)
To enable the water filter counter, follow this procedure:
1.
Switch off the machine through the main switch ( I.G. ).
2.
Switch on the machine through the main switch , keeping pressed at the same time the key n° 11 , 12 and 13 till the key
leds lights on.
The default liters setting is 2000 l.
To disable the water filter counter, follow this procedure:
1.
Switch off the machine through the main switch ( I.G. ).
2.
Switch on the machine through the main switch , keeping pressed at the same time the key n° 11 , 12 and 13 till the key leds
flashing.
When the setting liters are reached , the leds of the key n°11 , 12 and 13 will flash during the coffee delivery .
To carry out the water filter reset , follow this procedure :
1.
Switch off the machine through the main switch ( I.G. ).
2.
Switch on the machine through the main switch , keeping pressed at the same time the key n° 11 , 12 and 14 till the key leds
light on in sequence from left to right.
+
-