Troubleshooting
7.2 DEFINITION OF ERRORS AND ALARM LEVELS
SYMBOLS
LEVEL
DESCRIPTION
High
Main problem for the machine.
Medium-high
The problem can be solved and requires the switching off
of the machine to restore the normal operation.
Medium-low
The problem can be solved and does not requires the
switching off of the machine. The normal operation is re-
stored by solving the problem.
Low
Warning message for the operator.
Error
NO.
POSSIBLE CAUSE
INTERVENTION
2
Piston motor waiting time-out for
failure to reach the bottom position.
Check motor.
3
Time-out of piston top positioning.
Check encoder.
5
Piston motor waiting time-out for
failure to reach the top position.
Check motor.
7
Top slider waiting time-out for
failure to reach the closing position.
Check sensors.
Check slider motor.
8
Top slider waiting time-out for
failure to reach the closing position.
Check slider motor.
9
Piston motor waiting time-out for
failure to reach the top position.
Check motor.
Check encoder card.
10 - 11
7LPHRXWHUURUVRIÀRZPHWHUGXULQJGLVSHQVLQJ
(UURU&RQFHUQLQJWKHZDWHUSXOVHV
(UURUFRQFHUQLQJWKHH[WHQVLRQZDWHUSXOVHV
&KHFNÀRZPHWHU
12
Top slider waiting time-out for failure to reach the
opening position.
Check sensors.
16
Piston motor waiting time-out for
failure to reach the bottom, initial position.
Check encoder card.
7.3 ESPRESSO GROUP ERRORS
ESPRESSO GROUP ERROR - X
ERROR
11:25
|
19 February 2017
131°
Error page
Summary of Contents for BlueDotPlus
Page 1: ...MAINTENANCE MANUAL Translation of original instructions BlueDot Plus...
Page 2: ......
Page 5: ...3 Table of contents MANUAL REVISION DATE MODIFICATIONS First edition...
Page 6: ...4 Table of contents Page intentionally left blank...
Page 18: ...1 12 Introduction Page intentionally left blank...
Page 36: ...2 18 Description of the machine Page intentionally left blank...
Page 248: ...5 122 Programming Page intentionally left blank...
Page 260: ...7 10 Troubleshooting Page intentionally left blank...
Page 261: ......