CL-MC-XE1-IP-Y Series (1/2/4 E1) User Manual
- 18 -
#Configure an ip address for the WAN port
srcnet 172.16.1.1 255.255.255.0
#Configure an ip address and gateway for the NMS port
ipset 192.168.1.11 255.255.255.0 172.16.1.2
#Enable LAN port and set the bandwidth to 400Kbps.
lanset 1 7
#Save the configuration
csave
Script for setting
CPE
site configuration back to default I
gci
srcnet 172.16.1.2 255.255.255.0
ipset 192.168.2.11 255.255.255.0 172.16.1.1
lanset 1 7
csave
B) Script for resetting CL-MC-XE1-IP-Y to default II
Script for setting the device back to default II
(Enable E1 port#1 and set LAN bandwidth to 400 kbps)
Script for setting
CO
site configuration back to default II
gci
srcnet 172.16.1.1 255.255.255.0
ipset 192.168.1.11 255.255.255.0 172.16.1.2
#Set both transmitting and receiving pseudowire ID to 1 for E1 port#1
cespwidset 1 1 1
#Set the transmit packet size to 782 byte for E1 port#1
#Usage: pktsize ch_no pkt_size(0~3) !
#pkt_size(total len)=> (0: 1514 Byte, 1:782 Byte,
# 2: 178 Byte, 3: 306 Byte)
pktsize 1 1
#Set the jitter buffer depth to 11.5 msec for E1 port#1
#Usage: jitterbd ch_no depth !
#depth(pktsize=0)(0: 11 ms, 1: 23 ms, 2: 40 ms, 3: 75 ms,