22
ENG
“ultimateSAM - design” +03U0071EF - rel. 2.0 - 20150301
A further kit is available that is used to connect two SA0* (single-pipe)
distributors to one single inlet and consequently use just one set of
accessories rather than two. This kit also allows the desired flow-rate to be
reached (otherwise not possible with one upright), splitting the inlet flow-
rate between the two distribution systems, and thus increasing the flow-
rate as well as the efficiency of the system.
5 6 7 8
9
10
Family prefix
SAKD 0
0 x 0
x
x
Pos.
Meaning
Option
Description
Wt (kg)
Centre-to-centre
distance mm (in)
1
235 mm (9.251 in)
3.2
2
420mm (16.535 in)
3.3
For the dimensions and weights of the adapters, see the “Technical
specifications”.
H
L
H
L
H
L
L
250 mm
Kit SAKD0*10*0: (centre distance 235mm(9.3in))
Flow ≤ 50kg/h (110lb/h)
H=150mm (5.9in) L=160mm (6.3in)
Minimum height: 535mm (21.1in)
Flow ≥ 50kg/h (110lb/h)
H=200mm (7.9in) L=200mm (7.9in)
Minimum height: 635mm (25.0in)
Kit SAKD0*20*0: (centre distance 420mm(16.5in))
Flow ≤ 50kg/h (110lb/h)
H=150mm (5.9in) L=420mm (16.5in)
Minimum height: 720mm (28.3in)
Flow ≥ 50kg/h (110lb/h)
H=200mm (7.9in) L=420mm (16.5in)
Minimum height: 820mm (32.3in)
H
L
H
L
H
L
L
250 mm
Kit SAKD0*20*0: (centre distance 420mm(16.5in))
Flow ≤ 50kg/h (110lb/h)
H=150mm (5.9in) L=420mm (16.5in)
Minimum height: 820mm (32.3in)
Flow ≥ 50kg/h (110lb/h)
H=200mm (7.9in) L=420mm (16.5in)
Minimum height: 870mm (34.3in)
Note:
kit not available for the North American market
5.2 Steam inlet kits available
Table 5.b provides a list of all the steam inlet kits available to create the
connections with different types of piping. The table also provides details
on the type of connection for each adapter.
For installations that require an extension on the steam inlet, a special 150
mm adapter is available (SAKIX80100).
This adapter has the same flange at both ends (see Figure 4.b).
Steam inlet connections
Regions
Size
“****E***0*
****P***0* “
****T***0*
****P***U*
****E***U*
SAKI*401*0
SAKI*402*0
SAKI*404*0
not avail.
for 40 mm
tubing
not avail.
not avail.
SAKI*441*0
G Male
not avail.
NPT Male
NPT Female¹
SAKI*641*0
G Male
not avail.
not avail.
not avail.
SAKI*801*0
not avail.
for 80 mm
tubing
2
not avail.
not avail.
SAKI*841*0
G Male
not avail.
NPT Male
NPT Female¹
SAKI*941*0
G Male
not avail.
not avail.
not avail.
Tab. 5.c
¹SAKIE***U* comprises a SAKIP***U* connected to a threaded female-
female elbow.²Use this adapter to connect ultimateSAM to a 3” copper pipe,
as the 80 mm rubber hose can slide onto the outside of the 3” pipe.
5.3 Steam inlet connection between
ultimateSAM and valve flange
(SAKI******)
Connection kits are available for ultimateSAM between the distributor
steam inlet and the valve flange.
These kits vary depending on the distributor steam inlet connection and
valve nominal diameter.
1
Family prefix
SAKIC
0
x
x x
x
2 3
Pos.
Meaning
Opt.
Description
Type of connection
64
1 1/2”
84
2”
94
2 1/2”
Nominal diameter
A
DN 15
B
DN 20
C
DN 25
D
DN 32
E
DN 40
F
DN 50
G
DN 65
Region
U
North America
0
Other
Tab. 5.d
The kits are available in AISI 316 stainless steel
The kit codes specified in Table 2.e comprise:
•
gasket (1);
•
flange (2);
•
adapter (6);
•
pipe (3 , 5);
•
joint (4);
Summary of Contents for SA0AALI000