Carefree of Colorado
Service Manual
M
IRAGE
052979-301r16
18
D04
A
R
EMOTE
D
OES
N
OT
O
PERATE
(
STANDARD
E
LECTRONICS W
/
O
PTIONAL
R
EMOTE
)
1
Confirm normal operation with switches
If system does not operate, go to test
D01
2 Confirm batteries in remote are good. Pressing any
button on the remote will illuminate the LED indicator on
the remote
Replace as needed
4
Confirm that the receiver is programmed for the remote
--
Refer to “Programming the remote on
page 4 and retest. If system does
not work; go to step 4
5
Program a second remote and test
YES
2
nd
remote works. 1
st
remote is
defective.
NO 2
nd
remote does not work; control box
receiver is defective - replace
D04
B
R
EMOTE
D
OES
N
OT
O
PERATE
(D
IRECT
R
ESPONSE
)
1
Confirm normal operation with touch pad
If system does not operate, go to test
D01
2
Check the cable between the RR24 and control box. As a
continuity check, Pin 1 of connector 1 goes to Pin 1 of
connector 2; pin 2 goes to pin 2; pin 3 goes to pin 3 and pin 4
goes to pin 4.
Cable must be plugged into the "BUS" port of controller #1.
YES
Cable is OK. Confirm that cable is
securely plugged in; go to step 4
NO
Repair or Replace cable as required.
3
Confirm that the RR24 is programmed for the Remote
--
Refer to “Programming the Receiver”
on page 5 and retest. If system does
not work; go to step 5
4
Program a second remote and test
YES
2
nd
Key FOB works. Replace battery
in 1
st
Key FOB and retest, if no
response, 1
st
Key FOB is defective.
NO 2
nd
remote does not work; go to step 6
5
Replace the Receiver and test.
(it will be necessary to program receiver for remote)
YES
System works OK. 1
st
receiver is
defective
NO
System does not work. Reinstall 1
st
receiver; go to step 7
6
Replace control box
--