Care of Sweden CuroCell Nova User Manual Download Page 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) National Pressure Ulcer Advisory Panel, European Pressure Ulcer Advisory Panel and Pan Pacific Pressure Injury 

Alliance. Prevention and Treatment of Pressure Ulcers: Quick Reference Guide. Emily Haesler (Ed.). Cambridge Media: 

Osborne Park, Western Australia; 2014. 

 

1.3 Other information 

 

Action plan Pressure ulcers 

For the best possible results when using this product, we recommend a structured and 

planned approach. Examples that can be applied to the use of our products can be found in 

the ‘Action plan for pressure ulcers’ guidelines.

 

 

Mattress guide 

This guide provides guidance to personnel and prescribers when choosing a mattress from 

Care of Sweden. CuroCell Nova is a mattress in function group C.  

 

This information can be obtained from our website, www. careofsweden.com, or ordered from 

Customer Services (see contact information on the final page). 

 

 

 

 

 

NOTE! 

 

For certain patients, such as amputees, are the recommended minimum weight not 

valid. These users may however have other requirements as the entire mattress is not 

being loaded. Please refer to sections 4.2, 4.3 and 4.4 for operating control. 

 

 

When used together with positioning pillows, read the user’s manual carefully to 

ensure correct positioning of the user. 

 

 

If you are using this product with an evacuation sheet, it is the user’s responsibility to 

ensure that it is safe to use for evacuation. 

 

 

Be careful when using bed rails or other protection on the bed so that the mattress 

does not become trapped or damaged. 

 

 

The mattress must not be lifted with a person lying on it or used for any other type of 

transport other than a possible evacuation using an evacuation sheet.

 

 

 

This mattress is unsuitable for use during x-ray examinations because of the risk of 

blurred images

 

or artefacts that may lead to diagnostic errors. 

 

Summary of Contents for CuroCell Nova

Page 1: ...User manual 2021 03 04 CuroCell Nova Alternating pressure mattress Item number user manual 95 001014...

Page 2: ...on 4 Product description 6 Assembly Installation 8 Operation 9 Cleaning and reconditioning 11 Storage 12 Maintenance 13 Troubleshooting 14 Technical description 15 Spare parts 17 Options and accessori...

Page 3: ...t in a manner that prevents it from becoming trapped or damaged NOTE Be particularly aware of trapping damage when using bed rails 5 Never use the product if the pump power cord or plug is defective t...

Page 4: ...to our products by reporting them immediately to us here at Care of Sweden The system has been tested and approved according to the following standards IEC 600601 1 IEC 60601 1 2 SS EN ISO 12182 SS E...

Page 5: ...Customer Services see contact information on the final page NOTE For certain patients such as amputees are the recommended minimum weight not valid These users may however have other requirements as...

Page 6: ...n 2 1 Pump and mattress 1 Mattress 2 CPR rapid deflation 3 Tubes 4 Pump connector 5 Pump Air cells 2 2 Pump 1 Connection tubes 3 Power cord 5 Suspension hook 2 On Off 4 Fuses 2 6 Filter 2 4 1 3 4 3 1...

Page 7: ...ed and the pressure is equalized over the cells This function makes all user movements as well as nursing and care of the user easier Power off on 1 0 Suitable air pressure is set with the comfort dia...

Page 8: ...2 Hang the pump at the foot end of the bed or place it on a flat sturdy surface Route the power cord so that there is no risk of it causing someone to trip being run over by the bed wheels or getting...

Page 9: ...programs see section 2 3 for details We recommend alternating mode by default 4 3 Comfort setting The air pressure in the mattress can be adjusted according to the users desire for comfort Always cons...

Page 10: ...highest step Wait 10 minutes and perform a new hand check 4 5 CPR In case of an emergency where CPR cardiopulmonary resuscitation is necessary Rapidly pull the CPR band Remove the tube connections on...

Page 11: ...Isopropanol 70 oxidating solutions or chlorine max 1 Excrements and blood spots must be removed immediately with cold water Carefully follow local instructions and usage instructions for the cleaner...

Page 12: ...g solutions or chlorine max 1 5 Wipe off and disinfect all the work surfaces with an alcohol based cleaning agent intended for this purpose 6 Put the mattress together by putting back the cell package...

Page 13: ...s 7 2 Changing fuses 1 Pull the plug out of the electrical socket before replacing fuses 2 Remove the cover for the fuses with a screwdriver Pull out the fuse holder 3 Fit a new fuse of the same type...

Page 14: ...check see section 4 4 Mattress moves around Check that the air mattress is secured to the underlying mattress with the elastic straps Some cells have less air This is normal since the air flow alterna...

Page 15: ...ospheric pressure 700hPa 1013 25hPa Classification Class II Type BF IP2X MATTRESS SPECIFICATION Model CuroCell Nova Dimension LxWxH 85x200x13 cm Weight 4 kg NOTE Care of Sweden retains the right to mo...

Page 16: ...CE marked acc to Medical Device Regulation MDR 2017 745 Machine wash at 95 C Tumble dry Place on top of existing mattress Do not iron Recommended user weight User information category Wipe off Year M...

Page 17: ...ries 11 1 Optionals PRIMA 6 An elevating pad that is placed underneath a mattress overlay for example CuroCell Nova air mattress 11 2 Accessories Art no Description CC 9091 Sturdy transport bag 11 3 O...

Page 18: ...e of its authorised technicians Only use spare parts that have been approved by Care of Sweden Use of non approved spare parts invalidates the warranty A warranty claim must be submitted to Care of Sw...

Page 19: ...19 14 Own notes...