IMPORTANT SAFETY PRECAUTIONS 

Read all instructions prior to use 

 

 

 

 

 

Warning! 

To minimize the risk of fire, electric shocks or bodily injury: 

 

1.

 

The product must only be used for its intended purpose as described in this manual. 

The product may not be combined, assembled or repaired with other parts (e.g. pump 

and mattress), accessories or spare parts other than those described in this manual or 

other documentation from Care of Sweden. 

 

2.

 

Do not use the product in wet rooms or where there is a risk of the pump coming into 

contact with water or another liquid. Never handle a pump that has come into contact 

with water/liquid. Pull the plug out of the electrical socket immediately and send the 

product to an authorized service technician for servicing.  

 

3.

 

DO NOT USE in the vicinity of or in contact with fire sources/hot surfaces, such as fire, 

burning cigarettes or hot lamps. Although the product has undergone fire testing, it 

could become damaged if it comes into contact with fire sources.  

 

4.

 

Position and use the product in a manner that prevents it from becoming trapped or 

damaged. NOTE: Be particularly aware of trapping damage when using bed rails.  

 

5.

 

Never use the product if the pump power cord or plug is defective, the pump casing is 

damaged or it is not functioning properly. Pay extra attention when using bed rails 

that no wires become trapped between the bed and the rail. Contact a service 

technician for examination and repair.  

 

6.

 

Regularly check product functionality through a hand check (see section 4.4).  

 

7.

 

Continual monitoring is required when the product is used for individuals needing 

special supervision, such as children.  

 

8.

 

The mattress is protected by a hygiene cover; avoid using multiple hygiene covers as 

this can affect the vapor permeability of the mattress.  

 

9.

 

The hygiene cover does not allow liquid or air to penetrate, but is vapor permeable. 

Make sure that the user is positioned correctly to avoid the risk of suffocation.  

 

10.

 

Prevent damage to the hygiene cover from sharp objects. 

 

11.

 

If the cover are supplied with handles on the long sides, theses handles are only to be 

used for lifting and moving the mattress itself. All other use will be at your own 

responsibility and is not covered by the

 

product warranty. 

Summary of Contents for CuroCell Nova

Page 1: ...User manual 2021 03 04 CuroCell Nova Alternating pressure mattress Item number user manual 95 001014...

Page 2: ...on 4 Product description 6 Assembly Installation 8 Operation 9 Cleaning and reconditioning 11 Storage 12 Maintenance 13 Troubleshooting 14 Technical description 15 Spare parts 17 Options and accessori...

Page 3: ...t in a manner that prevents it from becoming trapped or damaged NOTE Be particularly aware of trapping damage when using bed rails 5 Never use the product if the pump power cord or plug is defective t...

Page 4: ...to our products by reporting them immediately to us here at Care of Sweden The system has been tested and approved according to the following standards IEC 600601 1 IEC 60601 1 2 SS EN ISO 12182 SS E...

Page 5: ...Customer Services see contact information on the final page NOTE For certain patients such as amputees are the recommended minimum weight not valid These users may however have other requirements as...

Page 6: ...n 2 1 Pump and mattress 1 Mattress 2 CPR rapid deflation 3 Tubes 4 Pump connector 5 Pump Air cells 2 2 Pump 1 Connection tubes 3 Power cord 5 Suspension hook 2 On Off 4 Fuses 2 6 Filter 2 4 1 3 4 3 1...

Page 7: ...ed and the pressure is equalized over the cells This function makes all user movements as well as nursing and care of the user easier Power off on 1 0 Suitable air pressure is set with the comfort dia...

Page 8: ...2 Hang the pump at the foot end of the bed or place it on a flat sturdy surface Route the power cord so that there is no risk of it causing someone to trip being run over by the bed wheels or getting...

Page 9: ...programs see section 2 3 for details We recommend alternating mode by default 4 3 Comfort setting The air pressure in the mattress can be adjusted according to the users desire for comfort Always cons...

Page 10: ...highest step Wait 10 minutes and perform a new hand check 4 5 CPR In case of an emergency where CPR cardiopulmonary resuscitation is necessary Rapidly pull the CPR band Remove the tube connections on...

Page 11: ...Isopropanol 70 oxidating solutions or chlorine max 1 Excrements and blood spots must be removed immediately with cold water Carefully follow local instructions and usage instructions for the cleaner...

Page 12: ...g solutions or chlorine max 1 5 Wipe off and disinfect all the work surfaces with an alcohol based cleaning agent intended for this purpose 6 Put the mattress together by putting back the cell package...

Page 13: ...s 7 2 Changing fuses 1 Pull the plug out of the electrical socket before replacing fuses 2 Remove the cover for the fuses with a screwdriver Pull out the fuse holder 3 Fit a new fuse of the same type...

Page 14: ...check see section 4 4 Mattress moves around Check that the air mattress is secured to the underlying mattress with the elastic straps Some cells have less air This is normal since the air flow alterna...

Page 15: ...ospheric pressure 700hPa 1013 25hPa Classification Class II Type BF IP2X MATTRESS SPECIFICATION Model CuroCell Nova Dimension LxWxH 85x200x13 cm Weight 4 kg NOTE Care of Sweden retains the right to mo...

Page 16: ...CE marked acc to Medical Device Regulation MDR 2017 745 Machine wash at 95 C Tumble dry Place on top of existing mattress Do not iron Recommended user weight User information category Wipe off Year M...

Page 17: ...ries 11 1 Optionals PRIMA 6 An elevating pad that is placed underneath a mattress overlay for example CuroCell Nova air mattress 11 2 Accessories Art no Description CC 9091 Sturdy transport bag 11 3 O...

Page 18: ...e of its authorised technicians Only use spare parts that have been approved by Care of Sweden Use of non approved spare parts invalidates the warranty A warranty claim must be submitted to Care of Sw...

Page 19: ...19 14 Own notes...

Page 20: ...ternet www careofsweden com Address Care of Sweden AB P O Box 146 SE 514 23 Tranemo SWEDEN Visit address Fabriksgatan 5A SE 514 33 Tranemo SWEDEN Cargo address Byns v g 4A SE 514 33 Tranemo SWEDEN Sup...

Reviews: