xr 600
13
5)
Click on “
TREADMILL Basic Setting
” to see and set up the values.
Once values are set up, click on “
Write Basic Machine Setup
” to send to the machine the values just modified.
With this software it’s possible to change/set up the following values:
Total (km):
see the total km of machine;
Partial (km):
see the km made from last extraordinary lubrication;
Partial Value Setting (km):
see / set up the km when the treadmill must make the extraordinary
lubrication;
Pumps number to change oil can:
Pumps number after that the oil can alarm turns on;
Extraordinary lubrification pumps number:
Number of oil pumps during the extraordinary lubrication;
Starting Inclination:
It’s possible to change the starting inclination value;
Delta Inclination:
Inclination increment pushing “
+ inclination”
key;
Enable WiFi connection (RunnerConnect):
This feature is not available;
Enable RS232 connection (RunnerConnect):
Enable/Un-enable the RS232 connection by cable;
Last Extraordinary Lub. (km):
see the km when the treadmill made last extraordinary lubrication;
Oil can pumps number:
see / reset the oil can pumps number (one every turning on operation);
Maximum Speed:
It’s possible to change the machine maximum speed;
Maximum Inclination:
It’s possible to change the machine maximum inclination;
Minimum Inclination:
It’s possible to change the machine minimum inclination;
Imput Protocol Name:
It’s possible to set up the machine protocol;
Serial Speed:
It’s possible to set up the serial communication speed;
Serial Delay (ms):
It’s possible to set up the serial commands delay;
Unit of measurement speed:
It’s possible to change the unit of measurement speed (kmh or mph).