background image

 

1

PRECAUTIONS 

Before using this indicator, read this manual 
and pay special attention to all "WARNING" 
symbols: 

 

 

IMPORTANT

 

 

ELECTRICAL 

 

 

      WARNING 

INTRODUCTION 

Your low profile platform scale is designed and 
manufactured with quality and reliability.  
Optional inclined ramps may be installed for 
easy approach and exit of scale.  Four electronic 
load cells support the scale platform and are 
connected at a centrally located junction box 
where calibration adjustments may be made.  
These load cells are self-checking and 
environmentally sealed.  
 
A lifting eye bolt is shipped with selected scales 
and should be conveniently stored, along with 
the shipping bolts, after completion of scale 
installation. The shipping bolts and lifting eye 
bolt will need to be re-installed if scale is 
relocated in the future. 
 
Your low profile platform scale has been factory 
calibrated to perform within the specifications set 
forth in Handbook #44 issued by the United 
States Department of Commerce, National 
Institute of Standards & Technology, as a "legal 
for trade" weighing device.  If re-calibration is 
required upon completion of installation, such 
procedures should be performed by a scale 
technician familiar with calibration and 
performance requirements of Handbook #44. 
 
This manual provides instruction for unpacking, 
installing and calibration of your scale.  A 
Trouble Shooting Guide was written so you may 
isolate or correct a problem before calling a 
scale technician. 
 
Please read this manual thoroughly and pay 
special attention to the warning symbols. 
 
 

COPYRIGHT 

All rights reserved. Reproduction or use, without 
express permission, of editorial or pictorial 
content, in any manner, is prohibited. No patent 
liability is assumed with respect to the use of the 
information contained herein.  
 

TABLE OF CONTENTS 

 

Introduction ........................................................ 1 

Installation ......................................................... 2 

Calibration Procedure ........................................ 3 

Trim Adjustment ................................................ 4 

Trouble Shooting Guide..................................... 5 

Interconnection Diagram ................................... 6 

 
 
FCC COMPLIANCE STATEMENT 

This equipment generates uses and can radiate 
radio frequency energy and if not installed and 
used in accordance with the instructions in this 
manual, may cause interference to radio 
communications. It has been tested and found to 
comply with the limits for a Class A computing 
device pursuant to Subpart J of Part 15 of FCC 
Rules, which are designed to provide 
reasonable protection against such interference 
when operated in a commercial environment. 
Operation of this equipment in a residential area 
is likely to cause interference in which case the 
user, at his own expense, will be required to 
take whatever measures may be required to 
correct the interference. 
 

DISCLAIMER 

While every precaution has been taken in the 
preparation of this book, we assume no 
responsibility for errors or omissions. Neither is 
any liability assumed for damages resulting from 
the use of the information contained herein. All 
instructions and diagrams have been checked 
for accuracy and ease of application; however, 
success and safety in working with tools depend 
to a great extent upon the individual accuracy, 
skill and caution. For this reason, we are not 
able to guarantee the result of any procedure 
contained herein. Nor can we assume 
responsibility for damage to property or injury to 
persons occasioned from the procedures. 
Persons engaging the procedures do so entirely 
at their own risk. 
 

Serial Number 

______________________ 

Date of Purchase 

___________________

Purchased From 

____________________ 

___________________________________

___________________________________

___________________________________

RETAIN THIS INFORMATION FOR FUTURE USE

 

Summary of Contents for Floor Hugger

Page 1: ...c Platform Scale Owner s Manual CARDINAL SCALE MFG CO 1905 M142 O1 Rev D 203 E Daugherty Webb City MO 64870 USA 05 01 Ph 417 673 4631 Fax 417 673 2153 Printed in USA www cardinalscale com Technical Support Ph 866 254 8261 tech cardet com ...

Page 2: ...2 ...

Page 3: ...ability is assumed with respect to the use of the information contained herein TABLE OF CONTENTS Introduction 1 Installation 2 Calibration Procedure 3 Trim Adjustment 4 Trouble Shooting Guide 5 Interconnection Diagram 6 FCC COMPLIANCE STATEMENT This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions in this manual may c...

Page 4: ...al Scale should remain packed until you are ready to install it protecting it while being stored Remove shipping bands and packing material Make certain all packing material is removed Remove wooden box containing load cell cable from pallet Place on scale platform until further instructions are given BE CERTAIN scale location is level and free of debris Using the lifting eye bolt provided move sc...

Page 5: ...able to weight indicating instrument following instructions provided in instrument manual Make certain cable is not placed near heating or cooling ducts relay panels ovens or other types of electrical equipment All cables should be routed out of the way of normal traffic and secured to prevent accidental damage to operator and or instruments After connection has been made power up and zero weight ...

Page 6: ...t weight on the corner with the highest reading and adjust the appropriate trim potentiometer until the weight reading agrees with the lowest reading obtained in Step 5 7 Repeat Step 6 until all corners have the same weight reading 8 Replace screws securing the junction box cover and access plate Figure No 3 If two or more load cells must be replaced or scale needs an over all resealing of each co...

Page 7: ... SOLUTION Scale reads accurate weight to a point but will not register beyond that point Obstruction between floor and bridge Remove obstruction Cannot obtain repeatable readings A Scale not level B Bad or improper wiring C Bad load cell D Bad trim circuit board A Level Scale B Check wiring solder connections C Replace load cell D Replace trim circuit board One corner will not register correct wei...