background image

7

DISPLAY MESSAGES 

DISPLAY MEANING 

 

Low battery indication 

5::5a

E

2

prom Error 

5::0a

Zero count under 128 

AAAAAa

Over capacity (upper dashes) 

BBBBBa

Under capacity (lower dashes) 

:: a

Zero count over 65,000 

+91 a

Calibration span too high 

77777a

Power-on zero count under 
calibration zero (-10%) 

77777a

Power-on zero count over 
calibration zero (+10%) 

CARE AND MAINTENANCE

The heart of the PS-7 Digital Portion Scale is a precision load cell located in the center of the 
scale base.  It will provide accurate operation indefinitely if protected against overload of scale 
capacity, dropping items on scale, or other extreme shock. 

• 

DO NOT

 submerge the scale in water, pour or spray water directly on it. 

• 

DO NOT

 use acetone, thinner or other volatile solvents for cleaning. 

• 

DO NOT

 expose scale to direct sunlight or temperature extremes. 

• 

DO NOT

 place scale in front of heating/cooling vents. 

• 

DO

clean the scale with a damp soft cloth and mild non-abrasive detergent. 

• 

DO

 remove power before cleaning with a damp cloth. 

• 

DO

 provide clean AC power and adequate protection against lightning damage. 

• 

DO

keep the surroundings clear to provide clean and adequate air circulation. 

Summary of Contents for Detecto PS-11

Page 1: ...MODEL PS 11 DIGITAL PORTION SCALE OWNER S MANUAL CARDINAL SCALE MFG CO 8528 M310 O1 Rev A PO BOX 151 WEBB CITY MO 64870 04 04 PH 417 673 4631 FAX 417 673 5001 Web Site http www detectoscale com ...

Page 2: ......

Page 3: ...No patent liability is assumed with respect to the use of the information contained herein While every precaution has been taken in the preparation of this manual the Seller assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from use of the information contained herein All instructions and diagrams have been checked for accuracy and ease of app...

Page 4: ...2 ...

Page 5: ...he proper electrical outlet The scale is now ready for operation BATTERY PACK The scale uses a 7 2VDC 1200 mA built in rechargeable battery pack The PS 11 can operate for up to 24 hours of continuous use with a fully charged battery pack BATTERY CHARGING To recharge the battery pack the power supply must be connected to a AC power outlet and plugged into the scale It will take approximately 8 hour...

Page 6: ...on to indicate that the displayed weight is in 1 4 ounce g The g annunciator is turned on to indicate that the displayed weight is in grams The low battery annunciator is used with the battery operation It will turn ON to indicate that the batteries will soon need to be replaced KEY FUNCTIONS UNITS 1 Press to change the weighing units to the alternate units of measurement if selected during config...

Page 7: ...n for this function to be operational WEIGH Place the item to be weighed on the scale tray Wait a moment for the scale display to stabilize then read the weight TO RE ZERO THE WEIGHT DISPLAY To re ZERO tare the weight display press the ZERO key and continue The scale will re ZERO tare until the full capacity is reached The membrane keyboard is not to be operated with pointed objects pencils pens f...

Page 8: ...isable display will change to 4 Press the ZERO key and then the UNIT key 5 times The display will change to 1 5 Proceed to AUTOMATIC SHUTOFF To select OZ ounce only weighing units 1 With the display showing 1 press the ZERO key and then the UNIT key The display will change to show OZ 2 Press the ZERO key to display OZ status 3 Press the UNIT key to toggle between Enable display will change to 1 or...

Page 9: ...display will change to 1 10 Proceed to AUTOMATIC SHUTOFF AUTOMATIC SHUTOFF 1 With the display showing 1 press the press UNIT key The display will change to show 2 Press the ZERO key to begin selection of the automatic shut off time in seconds The display will change to show 3 Press the UNIT key to toggle through the selections or 4 When the desired time is displayed press the ZERO key The display ...

Page 10: ... 9 797 for the Gravity Compensation If the ais disabled the scale will use the value obtained from the factory and entered by the operator for the Gravity Compensation To change the Gravity Compensation value 1 Press the ON OFF key to turn on the scale 2 Press and hold the UNITS key 3 seconds to enter Gravity Compensation mode the display will show 9 797 or the current value 3 Enter the desired gr...

Page 11: ...will provide accurate operation indefinitely if protected against overload of scale capacity dropping items on scale or other extreme shock DO NOT submerge the scale in water pour or spray water directly on it DO NOT use acetone thinner or other volatile solvents for cleaning DO NOT expose scale to direct sunlight or temperature extremes DO NOT place scale in front of heating cooling vents DO clea...

Page 12: ...8 ...

Reviews: