Cardinal Health Alaris PK Directions For Use Manual Download Page 43

1000DF00005 Iss. 2

42/44

 Warranty

Cardinal Health, Alaris® Products ("Cardinal Health") warrants that:

(A) Each new infusion instrument (pump, controller or peripheral instrument) is free from defects in material and workmanship under 
normal use and service for a period of two (2) years from the date of delivery by Cardinal Health to the original purchaser.

(B) Each new accessory is free from defects in material and workmanship under normal use and service for a period of ninety (90) days from 
the date of delivery by Cardinal Health to the original purchaser.

(C) Each Mains Cable, Battery, Flow Sensor (ECD) and non-disposable probe is free from defects in material and workmanship under normal 
use and service for a period of ninety (90) days from the date of delivery by Cardinal Health to the original purchaser.

(D) Each new Thermometer is free from defects in material and workmanship under normal use and service for a period of one (1) year from 
the date of delivery by Cardinal Health to the original purchaser.

If any product requires repair during the applicable warranty period, the purchaser should communicate directly with its local Cardinal 
Health service centre to determine the appropriate service facility. Except as provided otherwise in this warranty, repair or replacement will 
be carried out at Cardinal Health’s expense. The product requiring service should be returned promptly, properly packaged, and postage 
prepaid by purchaser. Loss or damage in return shipment to Cardinal Health shall be at purchaser’s risk.

In no event shall Cardinal Health be liable for any incidental, indirect or consequential damages in connection with the purchase or use 
of any Cardinal Health product. This warranty shall apply solely to the original purchaser. This warranty shall not apply to any subsequent 
owner or holder of the product.

Furthermore, this warranty shall not apply to, and Cardinal Health shall not be responsible for, any loss or damage arising in connection with 
the purchase or use of any Cardinal Health product which has been:

(A) repaired by anyone other than an authorised Cardinal Health service representative;

(B) altered in any way so as to affect, in Cardinal Health’s judgement the stability or reliability of the product or has had the product’s serial 
or lot number altered, effaced or removed;

(C) subjected to misuse or negligence or accident; or

(D) improperly maintained or used in any manner other than in accordance with the written instructions furnished by Cardinal Health.

This warranty is in lieu of all other warranties, express or implied, and of all other obligations or liabilities of Cardinal Health, and Cardinal 
Health neither assumes nor authorises any representative or other person to assume for it any other liability in connection with the sale of 
Cardinal Health products.

CARDINAL HEALTH DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR 
FITNESS FOR A PARTICULAR PURPOSE.

Summary of Contents for Alaris PK

Page 1: ...Directions For Use English Alaris PK Syringe Pump...

Page 2: ...tting Started 14 Basic Features 19 Operations During Use 21 Alarms and Warnings 23 Prompts 24 Configured Options 25 Specifications 29 Compatible Syringes 30 Associated Products 30 Compatible Extension...

Page 3: ...escribed information for rate and dosing limits Pharmacokinetic and Pharmacodynamic Interactions among anaesthetic drugs are known but are not taken into account in the calculation of the plasma and e...

Page 4: ...ation based on clinical judgement When a concentration in the plasma compartment is targeted this is called open loop plasma targeted TCI When a certain concentration at the effect compartment is targ...

Page 5: ...l science Edited by Breimer DD Crommelin DJA Midha KK Noordwijk Amsterdam Med Press BV 1989 pp 573 586 2 Kruger Theimer E Continuous intravenous infusion and multicompartment accumulation Eur J Pharma...

Page 6: ...Vc 5 1 0 0201 x age 40 0 072 x lbm 55 V2 9 82 0 0811 x age 40 0 108 x lbm 55 V3 5 42 CL1 2 6 0 0162 x age 40 0 0191 x lbm 55 CL2 2 05 0 0301 x age 40 CL3 0 076 0 00113 x age 40 k10 Cl1 Vc k12 Cl2 Vc k...

Page 7: ...be printed reviewed and signed as proof of approval by an authorised person according to Hospital protocol Signed printout to be kept safe for use during verification procedure Release Data Set status...

Page 8: ...ON OFF RUN HOLD PURGE BOLUS MUTE PRESSURE OPTION Extension set hook Finger Grips Extension set hook Release lever for Rotating Cam Carrying Handle IR Communications port RS232 Connector Folded Pole C...

Page 9: ...key to operate PURGE the extension set during set up Pump is on hold Extension set is not connected to the patient Volume Infused VI is not added BOLUS fluid or drug delivered at an accelerated rate P...

Page 10: ...onnector Optional Defibrillation proof type CF applied part Degree of protection against electrical shock O Protected against vertically falling drops of water r Alternating Current s Device complies...

Page 11: ...Selecting the MORE softkey will display the following additional information Patient Parameters Time to End of Infusion at Current Rate Volume and Dose Infused Elapsed Time Drug Name and Model Press...

Page 12: ...played on protocol confirmation screen E Duration of Hands Free Bolus Displayed in bolus set up screen F Maintenance Phase Dose Rate Displayed on protocol confirmation screen SOFT ALERT Indicates the...

Page 13: ...ould regularly monitor the progress of the infusion syringe extension line and patient connections and follow the priming procedure specified herein Operating Environment When using any infusion pump...

Page 14: ...trained technical personnel Consult Technical Service Manual for further information Hazards B An explosion hazard exists if the pump is used in the presence of flammable anaesthetics Exercise care t...

Page 15: ...hours to ensure that the internal battery is charged verify that the S is lit Language Selection 1 On initial start up the pump will display the Select Language screen 2 Select the required language f...

Page 16: ...cking Station Asena IDS Docking Station and Alaris Gateway Workstation Docking Station Workstation or Equipment Rail Installation Rectangular bar Rotating cam Release lever push to release Getting Sta...

Page 17: ...the syringe clamp and the syringe flange clamp This is correct if the syringe remains in position before the syringe clamp is closed 2 Insert the syringe ensuring that the barrel flange is located in...

Page 18: ...luid flows and the purging of the extension set is complete Release the softkey The volume used during purging will be displayed 12 Connect To Patient Connect the extension set to the patient access d...

Page 19: ...e cap rate will be cleared when first titration occurs 11 Target Concentration Cpt or Cet Adjust the Target Concentration if necessary using the f keys Confirm the Target Concentration and Initial Inf...

Page 20: ...ted The bolus volume is limited in the con guration 1 During infusion press the i button once to display the bolus screen 2 Use the f keys to adjust the bolus rate if required 3 To deliver the bolus p...

Page 21: ...nfusing at the new rate If Rate Titration is disabled the rate can only be adjusted whilst on hold 1 Press the h button to put the pump on hold 2 Select the new rate using the f keys 3 Press the b but...

Page 22: ...e initial doserate will be set to zero TREND SIZE The user is able to select the Trend Size of the Concentration Prediction graph 1 Press the d button to access the options menu 2 Using the f keys sel...

Page 23: ...softkey indicated on the screen A confirmation screen will be displayed DATA SET DETAILS To review the currently selected Data Set information 1 Press the d button to access the options menu 2 Select...

Page 24: ...F INFUSION The pump has reached the end of the infusion A pre set volume will remain in the syringe to minimise the risk of the infusion of air bubbles into the set This value can be configured TITRAT...

Page 25: ...OVERRIDE LIMIT is not required press the NO softkey and adjust rate below Soft Alert BOLUS DOSE OVER The bolus dose has been set to a value which exceeds a Soft Alert Check the bolus setting to conti...

Page 26: ...u Language This option is used to set the language of messages shown on the pump display 1 Select LANGUAGE from the Configured Options menu using the f keys and press the OK softkey 2 Use the f keys t...

Page 27: ...splay Purge Rate The rate used during purge operation Purge Volume Max The maximum permissible purge volume Purge Syringe Prompt Feature which prompts the user to purge the extension set prior to the...

Page 28: ...meters Induction ON OFF Enables Disables induction stage of TIVA protocol Dosing Units The induction dose units This can be based on patient weight Default Dose The default induction dose offered Defa...

Page 29: ...Maintenance Hard Max 20mg kg h 20mg kg h 2 g kg min 2 g kg min 2 g kg h Default Bolus Rate 1200ml h 600ml h 600ml h 600ml h 1200ml h Default Bolus 1 0mg kg 1 0mg kg 1 0 g kg 1 0 g kg 0 15 g kg Bolus S...

Page 30: ...ump is connected to AC power Battery life is typically 4h from fully charged 5 0ml h 20 C under normal conditions Charging takes 2 hours from discharge to 90 charge In TCI mode a fully charged battery...

Page 31: ...sed syringe with a large diameter barrel To provide protection against accidental dislodging always ensure the infusion line is secured using the infusion set hook see Loading a Syringe section TYCO H...

Page 32: ...lve low priming volume 209cm MFX 2291 2 way set with anti syphon valve and backcheck valve low priming volume 209cm MFX 2284 3 way tap blue with extension 100cm MFX 2280E 3 way tap with extension and...

Page 33: ...in accordance with the information supplied Cardinal Health will not be responsible should any of these actions be performed outside the instructions or information supplied by Cardinal Health Refer...

Page 34: ...ensure that the internal battery is fully charged A Before cleaning always switch OFF and disconnect from the AC power supply Never allow liquid to enter the casing and avoid excess fluid build up on...

Page 35: ...ssure Time to alarm following occlusion is achieved in less than 30 minutes at rates of 1 ml h and higher by the appropriate selection of occlusion levels The following graphs show the typical values...

Page 36: ...nddigitalcomponents are required to meet IEC EN60950 for data processingandIEC EN60601formedicaldevices Anyone connecting additional devices to the signal input or output is a system configurator and...

Page 37: ...e As the observation window is reduced short term fluctuations have greater effects as represented by the mouth of the trumpet Knowledge of system accuracy over various observation windows may be of i...

Page 38: ...than 5 2 By measuring the volume from the flow rate profile delivered from the Alaris PK Syringe Pump and then introducing this into a reverse pharmacokinetic model the predicted plasma or effect con...

Page 39: ...umetric Accuracy 0 4 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 0 5 10 15 20 25 30 35 40 45 50 55 60 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 0 5 10 1...

Page 40: ...lasma Concentration ng ml Ideal Plasma Concentration g ml 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 0 5 10 15 20 25 30 35 40 45 50 55 60 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 Patient Age 75 Yrs Patient Weight...

Page 41: ...n the Alaris Infusion System product family are 1 are also available without an RS232 option fitted contact local customer services representative to obtain part number details 2 For Docking Stations...

Page 42: ...Ndabeni Cape Town 7405 South Africa Tel 27 0 860 597 572 Tel 27 21 510 7562 Fax 27 21 5107567 BE Cardinal Health Otto De Mentockplein 19 1853 Strombeek Bever Belgium Tel 32 2 267 38 99 Fax 32 2 267 99...

Page 43: ...d promptly properly packaged and postage prepaid by purchaser Loss or damage in return shipment to Cardinal Health shall be at purchaser s risk In no event shall Cardinal Health be liable for any inci...

Page 44: ...31 F Fuses 32 G General Options 25 H Hands Free 19 Hands On 19 I Indicators AC POWER 8 BATTERY 8 Installation 15 Introduction 2 IrDA 35 L Labelling Symbols 9 Language 14 25 Loading a Syringe 16 M Mai...

Page 45: ...1000DF00005 Iss 2 44 44 Page Intentionally Left Blank...

Page 46: ...ment contains proprietary information of Cardinal Health Inc or one of its subsidiaries and its receipt or possession does not convey any rights to reproduce its contents or to manufacture or sell any...

Reviews: