CARBEL I 100 Manual For Use And Maintenance Download Page 15

 
 

13 

 

 
 
When  the  pipes  run  through  the  inside  of  the  home  or  a  brick  chimney,  they  should  be  mounted  as  shown  in 
Figure 1 to prevent liquids produced by the condensation of the gases flowing through the joints and out of the 
pipes. If a pipe section runs outside the building it must be mounted in the direction shown in Figure 2 to prevent 
rainwater draining down the outside part of the pipe and entering into the pipe interior through the joints 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

2.2 Exterior air inlet 

 
For the fireplace draught to work correctly, the room must have an outside air inlet from the house exterior to 
the room, that is at least sufficient to replenish the volume of air that comes out of the chimney flue.  
The house must always have an outside air inlet always enabled. 
Air  inlet  must  be  fitted  through  the  outer wall  and  if  a  vent  is  installed,  it  must  be  fitted  in  such  a  way  that  it 
cannot be blocked. 
 

 

 Warning. - 

In homes without the appropriate outside air inlet, extraction fans (e.g. Kitchen extractors) can cause 

problematic reverse chimney draughts.  

  

 

 

Connecting outside air inlet (OPTIONAL). 

 
The air inlet for combustion of this model is prepared to connect to an air intake duct outside the house (2). 
This ensures a better performance of the stove in any condition. 

 
The air inlet for combustion (2) and the convection air inlet (6) must not be shared inside the chamber of the 
masonry chimney. The convection air (6) must be taken from outside masonry chimney. 
 

 Warning.  -

  When  the  air  inlet  from  the  outside  is  not  enabled,  the  air  must  be  taken  from  outside  of  masonry 

chimney chamber, or sufficient air intake must be guaranteed in this chamber. 
 

Figure 1:  correct installation running on 
house interior. Liquids produced by gas 
condensation  do  not  flow  to  the 
exterior through the pipe joints 

  

 

Figure  2:  correct  installation  for  parts 
running on house exterior. Rain Water 
does  not  reach  the  inside  of  the  pipe 
through the pipe joints 

  

 

Summary of Contents for I 100

Page 1: ...INTENANCE Modelos I 100 I 80 I 70 CERTIFICACI N SEG N LA NORMA EN 13240 Y EN 13229 CERTIFICATION ACCORDING TO THE STANDARD EN 13240 Y EN 13229 Cocinas CARBEL S L C Ciudad de Cartagena 22 Pol gono Indu...

Page 2: ...ma de las entradas de aire P 10 4 MANTENIMIENTO P 10 5 CONSEJOS DESHOLLINADO Y NORMAS DE SEGURIDAD P 10 ENGLISH 1 NOTE FROM THE MANUFACTURER P 12 2 INSTALLATION P 12 2 1 Recommendations for the chimne...

Page 3: ...ONNECTION ASSEMBLY ANEXO IV SUJECCI N DEL APARATO A LA PARED Y SUELO P 26 ATTACHMENT OF THE DEVICE TO THE WALL AND FLOOR ESQUEMA ELECTRICO P 28 ELECTRIC DRAWING DATOS TECNICOS TECHNICAL DATA SHEET Mod...

Page 4: ...n medida de la instalaci n que se realice 2 1 Consejos para la chimenea El buen funcionamiento depende del tiro de la chimenea Le damos unos consejos pr cticos para conseguir un funcionamiento ptimo L...

Page 5: ...lluvia no entra al interior del tubo por los empalmes del tubo 2 2 Entrada de aire exterior Para que la chimenea tenga un tiro correcto es necesaria la entrada de aire exterior de la vivienda a la sa...

Page 6: ...ning n caso de la instalaci n del mismo 1 Tubo para salida de humos 200 o 150 seg n modelo 2 Entrada de airea la c mara de la chimenea por convecci n natural 3 Entrada de aire a la c mara de convecci...

Page 7: ...quiere decir que debe realizar el encendido una carga de combustible peso de le a aprox aconsejado por el fabricante para cada modelo seguida por un ciclo de combusti n completo repitiendo cargas de c...

Page 8: ...uncionamiento deseado La le a m s fina de menor calibre debe utilizarla para conseguir una mayor potencia t rmica util cela despu s del encendido para conseguir una respuesta m s r pida y cuando tenga...

Page 9: ...apa abundante de astillas o le a fina Debe dejar las piezas entrecruzadas y con suficiente espacio entre ellas para que circule aire 2 Encienda la capa superior de astillas o le a fina preferiblemente...

Page 10: ...mperatura del hogar de la estufa la calidad de la le a humedad tama o y forma 1 Regulaci n aire secundario 2 Regulaci n aire primario 3 5 REGULACION DURANTE EL ENCENDIDO Entrada de aire primario Es fu...

Page 11: ...l m ximo provecho a cada carga de le a Podr regular la entrada de aire secundario cuando el aparato este suficientemente caliente y la llama muy bien prendida Durante el funcionamiento normal nunca de...

Page 12: ...a estufa con limpia cristales agua ni productos especiales de limpieza La pintura antical rica no es impermeable Limpiar la pintura con plumero o un pa o suave y seco si con el tiempo desea restaurarl...

Page 13: ...el conducto 1 Prepare la le a dentro de la estufa para realizar el encendido 2 Coloque una pastilla o una hoja de peri dico sobre el deflector en la boca del inicio del conducto y pr ndalo 3 Transcurr...

Page 14: ...imal performance The wood burner must be connected to a flue that guarantees sufficient chimney draught at least 12 Pa The flue must have sufficient height not less than 4 m and should extend at least...

Page 15: ...h a way that it cannot be blocked Warning In homes without the appropriate outside air inlet extraction fans e g Kitchen extractors can cause problematic reverse chimney draughts Connecting outside ai...

Page 16: ...e responsible for the provided appliance but in no case for the installation of the same 1 Fumes exhaust pipe 200 or 150 according to model 2 Entry of air into the chimney chamber by natural convectio...

Page 17: ...at they should be lit loaded with an approximate weight of fuel as recommended by the manufacturer for each model followed by a full combustion cycle and fuel reloads after each combustion cycle Good...

Page 18: ...n it is not good and the glass tends to get dirty There is a danger of reaching excessive temperatures that threaten the integrity of the wood burner and user safety Select the firewood to achieve the...

Page 19: ...thin dry wood 1 Load a generous load of small or medium size open firewood with a generous layer of wood chips or thin firewood on top You should leave the pieces crossed and with enough separation be...

Page 20: ...ustion levels The optimal regulation of the air inlets can vary depending on various factors such as the chimney flue the temperature of the wood burner the quality of the wood moisture size and shape...

Page 21: ...R LEAVE OPEN 25 OF ITS RANGE 10mm Secondary air inlet Secondary air adjustment is the one that will provide better combustion that is cleaner and more efficient making the most of every load of firewo...

Page 22: ...er seals and cause oxidation of the metal parts It is very important not to wet the wood burner with window cleaner water or special cleaning products Heatproof paint is not waterproof Clean the paint...

Page 23: ...ighting the fire by heating the flue 1 Prepare the wood for lighting inside the wood burner 2 Place a firelighter or a sheet of newspaper on the deflector at the start of the flue and set fire to it 3...

Page 24: ...inas Carbel S L C Ciudad de Cartagena 22 Pol gono Industrial fuente del Jarro 46988 Paterna VALENCIA CERTIFICADO DE GARANTIA NOMBRE DIRECCION POBLACION COD POSTAL PROVINCIA TELEF EMAIL MATERIAL EXENTO...

Page 25: ...Carbel S L C Ciudad de Cartagena 22 Pol gono Industrial Fuente del Jarro 46988 Paterna VALENCIA CERTIFICATE OF WARRANTY NAME ADDRESS TOWN CITY POSTCODE PROVINCE TEL E MAIL MATERIAL EXCLUDED FROM WARR...

Page 26: ...de panels and take out the baffle 3 Con ayuda de unos alicates enderece las pesta as de seguridad del deflector superior de acero inoxidable y ret relo With pliers unbend the safety retaining hooks of...

Page 27: ...er using the holes already provided 2 Introducir las patas en las gu as Insert the legs into the guides 1 Regular la altura y fijarlas con los tornillos Para montar la caja de la turbina es necesaria...

Page 28: ...bilidad y sujeci n del aparato le recomendamos instalar las dos escuadras suministradas In order to ensure optimal stability and holding of the device we recommend that you install the two supplied br...

Page 29: ...izar las patas met licas debidamente dise adas para tal fin La elecci n de la torniller a adecuada ser competencia del instalador In order to guarantee the correct anchoring of the device to the floor...

Page 30: ...W Modelo I70 I80 KRONOS 70 KRONOS 60 A70 2 A80 2 2 POSICIONES N L T1 2 POSICIONES S1 V1 V2 V3 2 POSICIONES V4 N L V3 V2 T1 V1 2 POSICIONES S1 15 W 50 Hz 14 W 0 22 A Max POTENCIA INSTALADA 42 W TENSI N...

Page 31: ...s A ndice de eficiencia energ tica Energy Efficiency Index EEI 118 Rendimiento Performance 87 30 Potencia t rmica nominal Nominal Thermal Power 10 78 Carga de Le a para pot Nominal Firewood load for N...

Page 32: ...wood Load 2 9 Kg Peso Weight 95 kg Tiro necesario chimenea Required Chimney Flue 12 Pa Temperatura media de los humos Average Smoke Temperature 227 Modelo Model I 70 Clase energ tica Energy Efficiency...

Page 33: ...31...

Page 34: ...32...

Page 35: ...33...

Page 36: ...34...

Reviews: