![CARBEL C-100 Plus Double-sided Instruction Manual Download Page 3](http://html1.mh-extra.com/html/carbel/c-100-plus-double-sided/c-100-plus-double-sided_instruction-manual_2555535003.webp)
3
- When a metal chimney is fitted inside a brick chimney, it must exceed the height of the latter and protrude a few
centimetres at the top.
- The installation of the pipe and cap must strictly prevent water from getting into the appliance on rainy days.
Water causes more damage to woodburners than the high combustion temperatures for which they are prepared.
When the pipes run through the inside of the home or a brick chimney, they should be mounted as shown in
Figure 1 to prevent liquids produced by the condensation of the gases flowing through the joints and out of the
pipes. If a pipe section runs outside the building it must be mounted in the direction shown in Figure 2 to prevent
rainwater draining down the pipe and entering into the pipe interior through the joints.
Exterior air inlet
For the fireplace draught to work correctly, the room must have an outside air inlet that is at least sufficient to
replenish the volume of air that comes out of the chimney flue.
An air inlet must be fitted through the outer wall and if a vent is installed, it must not be adjustable and must be
fitted in such a way that it cannot be blocked.
Warning. In homes without the appropriate outside air inlet, extraction fans (e.g. kitchen extractors) can cause
problematic reverse chimney draughts.
General installation instructions
The installation of the appliance must comply with all local regulations, including those that refer to national and
European standards.
Although the following describes an example installation to ensure good performance, it may not be ideal for
your circumstances. In any case, it is always better to have a professional do the installation. If you are determined
to do your own installation, consult a professional.
1- Fumes exhaust pipe Ø 200 or 150, according to model.
2- Seal of the chimney hollow with rock wool.
3- Optional outlet for hot air to other rooms, blown by fans.
4- Facing the interior walls of the hood with rock wool.
5- Hot air outlet of the chimney chamber by natural convection.
6- Hot air outlet at the top of the front blown by fans.
7- Entry of cold air into the insert convection chamber sucked in by fans.
8- Entry of cold air into the chimney chamber by natural convection.
Summary of Contents for C-100 Plus Double-sided
Page 12: ...12...