CARBEL C-100 Plus Double-sided Instruction Manual Download Page 11

 

 

11 

TECHNICAL SPECIFICATIONS 

 

 
 

 

 

 

Model

 

Weight

 

Performance

Rated 

Power

Emissions of 

CO 13% O2

Firewood for 

Rated 

Power

Maximum 

Load

 

Reload 

interval for 

rated 

power

Draught 

required 

for chimney

Average temp. 
of fumes

Carbel C-60 

Plus

 

70 kg

80%

7.8 kW

0.12%

1.5 kg

2.5 kg

0.71 h

12 Pa

285 ºC

Carbel C-70 

Plus

 

85 kg

79%

9.1 kW

0.14%

1.8 kg

3 kg

0.73 h

12 Pa

292 ºC

Carbel C-80 

Plus

 

95 kg

78%

11.75 kW

0.14%

2 kg

 

3.7 kg

 

0.73 h

12 Pa

300 ºC

Carbel C-100 

Plus

 

125 kg

 

78%

14.4 kW

0.14%

2.9 kg

5.2 kg

 

0.73 h

12 Pa

308 ºC

Carbel C-70 

Plus

 

 Double-sided

110 kg

 

75.30%

8.6 kW

0.25%

2 kg

 

3.6 kg

 

0.75 h

12 Pa

331 ºC

Carbel C-80 

Plus

 

 Double-sided

120 kg

 

74.70%

10.7 kW

0.27%

2.5 kg

4.2 kg

 

0.75 h

12 Pa

349 ºC

Carbel C-100 

Plus

 

 Double-sided

150 kg

 

74.70%

12.8 kW

0.27%

3 kg

 

5.5 kg

 

0.75 h

12 Pa

349 ºC

Carbel H-69 S

 

75 kg

79%

9.1 kW

0.14%

1.8 kg

3 kg

0.73 h

12 Pa

292 ºC

Summary of Contents for C-100 Plus Double-sided

Page 1: ...s C 60 Plus C 70 Plus C 80 Plus C 100 Plus C 70 Plus Double sided C 80 Plus Double sided C 100 Plus Double sided CARBEL C Ciudad de Cartagena 22 46988 Pol gono Industrial Fuente de Jarro Paterna Valen...

Page 2: ...ce The woodburner must be connected to a flue that guarantees sufficient chimney draught The flue must have sufficient height not less than 4 m and should extend at least one metre beyond the maximum...

Page 3: ...tted through the outer wall and if a vent is installed it must not be adjustable and must be fitted in such a way that it cannot be blocked Warning In homes without the appropriate outside air inlet e...

Page 4: ...u will notice this in an increase in flames and temperature Woodburners and inserts are intermittent combustion appliances This means that they should be lit loaded with an approximate weight of fuel...

Page 5: ...void the smoke inside the fireplace from blowing out into the room Warning In woodburners and inserts prolonged and continuous use at a very low rate of combustion or with very wet wood can cause high...

Page 6: ...to maximum position when lighting the fire and to leave the door ajar to avoid the condensation of fumes on the glass closing it again once the appliance has warmed up In order to avoid burns always u...

Page 7: ...ace increases open the air inlet or repeat step 3 When you reload with more wood if there are not enough flames or embers to light the new load of wood repeat steps 3 and 4 Select the firewood to achi...

Page 8: ...fficient bearing capacity Observe the minimum safety distances from nearby combustible materials In front of the appliance minimum 90 cm Combustible materials must not be installed on the appliance or...

Page 9: ...view of the insert 1 2 3 4 5 6 Note the c 60 Plus model does not include brackets Steel deflector Vermiculite deflector Bracket x2 Remove the vermiculite deflector Remove the two brackets Remove the s...

Page 10: ...no draught you can adjust the steel deflector to evacuate fumes Note opening the deflector will reduce the performance of the insert Baffle C 70 Plus C 80 Plus C 100 Plus C 60 Plus Baffle Pre cut for...

Page 11: ...W 0 14 1 8 kg 3 kg 0 73 h 12 Pa 292 C Carbel C 80Plus 95 kg 78 11 75 kW 0 14 2 kg 3 7 kg 0 73 h 12 Pa 300 C Carbel C 100 Plus 125 kg 78 14 4 kW 0 14 2 9 kg 5 2 kg 0 73 h 12 Pa 308 C Carbel C 70Plus Do...

Page 12: ...12...

Page 13: ...13 Cocinas CARBEL S L C Ciudad de Cartagena 22 46988 Pol gono Industrial Fuente de Jarro Paterna Valencia Tel 96 1340716 Fax 96 1340449 E mail carbel carbel net...

Page 14: ...Carbel S L C Ciudad de Cartagena 22 Pol gono Industrial Fuente del Jarro 46988 Paterna VALENCIA CERTIFICATE OF WARRANTY NAME ADDRESS TOWN CITY POSTCODE PROVINCE TEL E MAIL MATERIAL EXCLUDED FROM WARR...

Reviews: