The machine is easy to move. Lift the handle and
move the machine on its wheels, as shown in Fig. 7.
AVOID UNEXPECTED STARTING
Make sure that the switch is turned off before
inserting the plug.
The machine is to be connected to the power supply
by a residual current circuit breaker (RCCB) or class
II isolation transformer with the following
characteristics:
RCCB
In 10A Id 20 mA
Transformer
230V 50Hz 1500 W
cont. Duty
N.B. To ensure correct functioning, periodically
check the efficiency of the RCCBs by pressing
the push-button on the front of the same.
Prior to connecting the machine to the power
supply, make sure that the voltage is the same as
indicated on the machine data plate. The machine
must be connected to an effective earth wire. In
case of doubt, do not connect the machine.
The MIXER 50S are provided with overheat
protection with manual reset. This intervenes in the
event of the agitator jamming. In the event of it
jamming, before resetting the thermal protection,
disconnect the machine from the mains electricity
supply.
Do not run the machine at full throttle. The machine
will generate its maximum output, whilst observing
safety conditions, only if it is used according to the
operating conditions for which it has been designed.
Proceed as follows to prepare the mixture:
•
Always start the machine only when it is empty.
•
Proceed as follows on the basis of the type of
component to be used.
Glue for floor and wall tiles
A)
Carefully read the instructions on the glue sack
you are going to use.
B)
Pour in the basket the quantity of water
necessary to prepare the desired glue quantity
following the manufacturer's instructions.
C)
Start the MIXER 50S , then tip the first 25 kg of
powder at a speed of 10 kg/m directly on the
plastic protection, which will centrifuge the
material to obtain an appropriate mixture.
Continue with this operation in a continuous and
uniform manner with the second sack (25 kg)
and wait for the whole product to be properly
mixed. In this way the past will be free from
lumps.
GB
18
7
7
8
8
4. Transport
5. Connecting to power supply
6. Preparation of the mixture
INFORMATION
CAUTION !