Page 3: ...44 Evaporator 2 13 DG7 3 1 BH Evaporator fan 2 14 DG22 209 Air duct board 2 15 DG19 1 Fan cover 2 16 DG13 198 Senser cover 2 17 DG8 8 Senser 2 18 DG3 12 W LED Light 2 19 DG13 383 Display holder 2 20 D...

Page 4: ...stlip 2 32 DG14 189 SR Lower hinge module Right 1 33 DG13 6 11 Cabinet leg 4 34 DG22 88 Support bracket of front legs 1 35 DG14 189 SL Lower hinge module Left 1 36 DG12 91 2 Condenser 1 37 DG12 113 A...

Page 5: ......

Page 6: ...ry protection well When servicing the wine cooler with R600a systems please make sure the ambient is well ventilated Preparation before maintenance Tools 1 Plier 2 Cross screwdraver 3 Assistant pipe 4...

Page 7: ...cooler and check the current again check the discharge pipe of the compressor at the same time if it has an clear air pressure if the electricity is still too high or has not air pressure it shows th...

Page 8: ...pressure pipeline is on the process pipe of the filter Apply the vacuum pump for approximately 20 minutes Until the vacuum is lower than 100Pa Then solder the process pipe of the filter Keep the the s...

Page 9: ...ews need not to remove and remove the air duct board Be attention to unplug the connection wire when removing the air duct board You can move slowly aside until you can see the fans wire and unplug th...

Page 10: ...ant pipe soldered jointed B Anti dew pipe soldered joint C Right zone suction pipe soldered joint D Discharge pipe soldered joint E Left zone suction pipe soldered joint F Condenser soldered joint G F...

Page 11: ...the fan s fault the reason is following a The axletree of the fan broken b The bad balance because the fans abrasion 3 The fan can be replace with another same model s fan the procedure is following a...

Page 12: ...ency impact noise in capillary Zone Caused by either Causation 1 The capillary being insert too deep into the evaporator so when the refrigerant is Jetting the end of vibrating capillary will hit the...

Page 13: ...t fix for the door Fig 7 The instability of the wine cooler temperature The unstable temperature is caused by the evaporator fans cease and it can be check by the below method When the compressor is r...

Page 14: ...ion wire and the main board whether short circuit if not replace the sensor with the same module See Fig 8 6 The LED display shows HI and it is the high temperature protection indication After running...

Page 15: ...ht is normal and another zone is not cooling or over low temperature lower than the temperature preset 3 or one zone is not cooling the other zone is over cold please check the refrigerant valve 2 Tur...

Page 16: ...trical box in right zone disconnect all connectors remove the main PCB The process of display PCB removed remove the shelves take apart the inner electrical box disconnect all connectors if necessary...

Page 17: ...ers on display board supporter 8 as per arrowhead direction and then remove the display board and its two connectors from both sides Replace the display board See Fig 11 Fig 12 The name and explanatio...