In Case of Power Cut
• All regulated parameters and functions are kept in memory when the power cut.
• When the electricity comes, if the defrost sensor temperature is lower than -5 ºC the
compressor works 5 minutes later. If it is higher than -5 ºC.
Other Features
Warnings
: The door open warning is active 2 minutes later and it alarms.
Door Direction : It is possible to reverse the door.
Gasket
: It is possible to change the gasket.
Freezer Defrosting Time
The Defrost is disabled when the defrost sensor temperature feels 8ºC.If defrost time
passes 37 minutes, defrost completing temperature will be rise to 15ºC.
The cooler defrost and the freezer defrost are operated parallel except those below. The
cooler defrost will not work if the freezer defrost stops.
The defrost process stops when the defrost sensor temperature feels 7ºC. At the low
ambient temperature or when the compressor stops; to balance, defrost stops when the
defrost sensor temperature feels 15⁰C. But if the defrost time or the compressor stopping
time goes over 6 hours, the resistance will be stopped.
Compressor delay: First, the defrost process ends, the system waits 5 minutes, just after that
the compressor is active.
Cooler Defrosting Time
RFF730 Caple 70/30 Freestanding Fridge Freezer