Resistance Values According To The Temperature Sensor (°C/Ohm Rates)
( For The Freezer Defrost and The Cooler Ambient Sensor)
45 °C/1kΩ
-1 °C/6.2kΩ
35 °C/1.5kΩ
-3 °C/6.8kΩ
30 °C/1.8kΩ
-5 °C/7.5kΩ
25 °C/2.2kΩ
-7 °C/8.2kΩ
19 °C/2.7kΩ
-12 °C/10kΩ
14 °C/3.3kΩ
-15 °C/12kΩ
10 °C/3.9kΩ
-20 °C/15kΩ
5.5 °C/4.7kΩ
-24 °C/18kΩ
1.5 °C/5.6kΩ
-31.5 °C/27kΩ
0 °C/6kΩ
-35.5 °C/33kΩ
Sensor Resistance Values According To The Temperature (°C/Ohm Rates)
(For The Cooler Defrost Sensor)
45 °C/2.15kΩ
-1 °C/17.1kΩ
35 °C/3.26kΩ
-3 °C/19kΩ
30 °C/4.02k12Ω
-
5 °C/21.1kΩ
25 °C/5kΩ
-7 °C/23.5kΩ
19 °C/6.53kΩ
-12 °C/30.8kΩ
14 °C/8.23kΩ
-15 °C/36.5kΩ
10 °C/9.95kΩ
-20 °C/48.6kΩ
5.5 °C/12.3kΩ
-24 °C/61.5kΩ
1.5 °C/15kΩ
-31.5 °C/98kΩ
0 °C/16.3kΩ
-35.5 °C/12.6kΩ
RFF730 Caple 70/30 Freestanding Fridge Freezer