U S E F U L W A R N I N G S :
› Use an air outlet pipe with a maximum length not higher than 5 meters.
› Limit the number of bends in the exhausting pipe as every bend reduces the performance
up to one linear meter. (If you use 2 90° bends, than the length of the pipe has got to be
higher than 3 meters).
› The material for the pipe has to be approved by an authorised company.
› It is important to avoid changes in the diameter (A minimum 150mm diameter ducting
must be used).
› Read carefully the manual of instructions and installation of the unit.-
› Caple will not be responsible for problems of capacity and/or noise level due to the missed
respect of the warnings included in the instruction manual.
› DDMEXT25 / 40 are equipped with a 200mm diameter hole for the exhausting pipe. If the
unit that has to be connected to the remote fan already equipped with a 200mm diameter
hole, then it is recommended to use a pipe with the same diameter in order to get good
performance. Otherwise, if the unit is equipped with a 150mm diameter hole, then it is
recommended to use the joint (from 200mm to 150mm), already supplied with the unit.
The electric box cable should not be cut or joined together with other cables, since it could
compromise the proper working and the safety conditions of the appliance. Furthermore,
this will invalidate the manufacturer’s warranty coverage.
CAUTION:
In order to know the exact power input in (WATT) of the motor being used, the technician shall
tick the box corresponding to the DDMEXT unit used on the label placed next to the rating
label, as shown in the figure below.