Instruction manual CR9209
12
Please keep this instruction manual for future reference
Converting from Natural Gas to LPG
To attach the appliance to a gas supply different from that for which it was set up (see gas type label inside the warming
compartment door) proceed as follows:
- Remove the pan supports
- Remove the burners caps and burner heads
- With a 7mm socket screwdriver unscrew and remove the injectors.
- Replace the injectors with those supplied corresponding to
the gas available (see Burner and Injector Characteristics table)
- Replace the various parts proceeding in reverse.
- Install with suitable hose compliant with the standards in force
The flame on the small output is regulated by the factory.
When the injectors have been replaced, it will be necessary to regulate the minimum flame.
To regulate the minimum flame do the following:
- Light the burner
- Turn the knob to the minimum position
- Take out the knob (and gasket if there is one)
- Using a thin blade screwdriver to turn the by-pass screw located in the brass shaft
(as shown right) turn screw fully clockwise then turn it anti-clockwise a 1/4 turn
for the triple burner and 1/8 turn for all other burners. The result should be a
small, stable flame which is uniform around the entire burner ring. If not, turn the
by-pass screw anti-clockwise until satisfied with the flame
- Place the knob back on securely and turn it quickly from the maximum position to
the minimum position, checking that the flame does not go out
- As the burners are fitted with a safety valve ensure the regulation obtained is
sufficient to maintain heating of the thermocouple. If this is not the case, increase
the minimum
- The burners do not require regulation of primary air.
Abnormal operation
ANY OF THE FOLLOWING ARE CONSIDERED TO BE ABNORMAL OPERATION AND MAY REQUIRE SERVICING:
- Yellow tipping of the hob burner flame.
- Sooting up of cooking utensils.
- Burners not igniting properly.
- Burners failing to remain alight.
- Burners extinguished by oven door.
- Gas valves that are difficult to turn.
If the appliance fails to operate correctly contact Caple Service e: [email protected] t: 0117 938 7420 .
CR9209 - Instruction Manual.indd 12
27/04/2017 10:38