Biphase (400V~ 2P+N):
For a Biphase connection, Live wires 1 & 2 will need to have the same Live mains supply, and
Live wire 3 will have its own separate connection. The Neutral and Earth can be connected into
their relevant mains connectors.
Triphase (400V~ 3P+N):
For a Triphase connection, each Live wire will require its own separate Live mains supply. The
Neutral and Earth can be connected into their relevant mains connectors.
Caution!
Ensure that the cables are correctly installed and sufficiently tightened.
4 weeks after installation, a check should be made to ensure the electrical
cables are still connected tightly and tightened further if necessary.
We cannot be held responsible for any incident resulting from incorrect connection,
which could arise from use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.