3
Fitting Your Hob
Technical Information
How to Install Your Hob
1. The hob requires a space in the kitchen work surface as shown in the diagram (Fig.
1) below:
●
Minimum distance of hob to back wall
50 mm.
●
Minimum distance of hob from only
vertical surface either side of the hob
150 mm.
●
Minimum height of adjacent units
either side of the hood must be a mini-
mum of 366 mm above the work sur-
face.
●
Minimum height of a cabinet directly
above hob if not fitting a hood 900 mm.
●
Minimum of 650 mm from the hob to
a cooker hood.
Do not fit above refrigeration products.
This appliance has type “Y” overheating
surrounding surfaces protection.
Fig. 1
575
505
560
490
52
Mod. C 901 H/W, C 901 H/B:
Total absorbed power
6.2 kW
Halogen Plate 145 mm
1.2 kW
Halogen Plate 180 mm
1.8 kW
Radiant Plate 145 mm
1.2 kW
Radiant Plate 195 mm
2.0 kW
Voltage
230 V
Mod. C 801 C/W, C 801 C/B:
Total absorbed power
6.0 kW
Quickstart Plate 145 mm x 2
1.2 kW
Quickstart Plate 180 mm
1.7 kW
Quickstart Plate 195 mm
1.9 kW
Voltage
230 V