INSTALLATION
IMPORTANT NOTICE:
THE OPERATIONS INDICATED BELOW MUST BE FOLLOWED BY QUALIFIED
PERSONNEL ONLY, IN CONFORMITY WITH THE REGULATIONS IN FORCE.
CAPLE REFUSES ALL RESPONSIBILITY FOR DAMAGES TO PEOPLE, ANIMALS OR
OTHERS, RESULTING FROM THE FAILURE TO COMPLY WITH SUCH PROVISIONS.
INSTALLING THE HOB
The appliance is designed to be installed into heat-resistant furniture. The walls of
the furniture must be able to withstand a temperature of 75°C.
The equipment must not be installed near inflammable materials, such as curtains,
cloths,etc.
Make a hole in the worktop of the dimensions indicated in the “Installation
Dimensions” (Pg. 20-21) respecting a minimum distance of at least 50mm from the
rear edge of the hob and 100mm of the adjacent side walls.
Any wall unit or extractor over the hob must be placed
at a distance of at least 760mm from the hob. It is
advisable to isolate the appliance from the piece of
furniture below with a separator, leaving a ventilation
space of at least 120cm
2
.
When installing on a built-in oven without forced ventilation, ensure that there are air inlets and outlets for
ventilating the interior of the cabinet adequately.
Gas connection for gas hob
The hob should be connected to the gas-supply by a Gas safe registered installer. During installation of this
product it is essential to fit an approved gas tap to isolate the appliance from the supply for the convenience
of any subsequent removal or servicing. Connection of the appliance to the gas mains or liquid gas must be
carried out in compliance with current regulations, and only after it is ascertained that it is adaptable to the
type of gas to be used. If not, follow the instructions indicated in the paragraph headed "Adaptation to
different gas types". In the case of connection to liquid gas, by bottle/tank, use pressure regulators that
conform to current regulations in force.
Important:
For safety, for the correct regulation of gas use and long life of the appliance, ensure that the
gas pressure conforms to the indications given in table 1 "Burners and injector specifications".
Connection to Gas supply by rigid metal pipe
(Copper or steel)
Connection to the gas source must be done in such a way as to not create any stress points at any part of
the appliance.
The appliance is fitted with a 1/2” gas male ‘L’ shaped union and a gasket for the attachment to the gas
supply.
Should this union have to be re-positioned, the gasket must be replaced.
Connection to flexible steel tube
The gas feed connector to the appliance is a threaded, male 1/2" connector for round gas pipe. Only use
pipes and sealing gaskets that conforms to the standards currently in force. The maximum length of the
flexible pipes must not exceed 2000 mm. Once the connection has been made, ensure that the flexible
metal tube does not touch any moving parts and is not crushed.
Check the Installation
Once the appliance has been installed, make sure all the connections are properly sealed, using liquid
detector fluid and a ‘U’ gauge. Never use a flame.
Electrical Connection
(The hob is fitted with a standard 13amp plug)
Fit the supply cable with a standard plug for the demand rate indicated on the rating plate or connect it
directly to the electrical mains. In the latter case, a single pole switch must be placed between the appliance
and the mains, with a minimum opening between the contacts of 3 mm in compliance with current safety
codes (the earth wire must not be interrupted by the switch). The power supply cable must be positioned so
that it does not reach a temperature in excess of 50~C above room temperature at any point.
Before actual connection make sure that:
fig 3