Instruction manual C3371
Instruction manual C3371
14
15
Please keep this instruction manual for future reference
Please keep this instruction manual for future reference
E L E C T R I C A L C O N N E C T I O N
F I T T I N G T H E P OW E R S U P P LY C A B L E
-
Open the terminal box by inserting a screwdriver into the side tabs of the cover. Use the
screwdriver as a lever by pushing it down to open the cover
-
Install the power supply cable by loosening the cable light screw and the three wire contact
screws. Connect the wires to the corresponding terminals:
the Blue wire to the terminal marked ‘N’,the Brown wire to the terminal marked ‘L’ and the
yellow/green wire to the terminal marked .
-
Secure the cable by fastening the clight screw.
-
Close the cover of the terminal box.
-
When wiring the terminal box care must be taken to fit and tighten the links on the live (L) and
neutral (N) terminals
L
N
W I R I N G A N D S A F E T Y
The instructions given below
MUST
be adhered to during wiring:
-
This appliance is designed to connect to 220-240V~ and is rated at 32Amps and as such needs
to be hard wired to the electrical supply.
-
If the electrical supply is different from the value given above, call Caple Service immediately.
-
Wiring of the appliance must be performed by a qualified installer/electrician.
-
The earth cable must be connected via the terminal screw with the earthing mark. Supply
cable connection must be as shown in the diagram. If there is no earthed outlet conforming to
regulations in the installation environment, the installation cannot go ahead and an Electrician
should be consulted immediately.
-
The installation must include a suitable isolating switch with a minimum contact opening of
3mm between the appliance and the mains. The isolating switch should be sized according to the
load on the rating plate “32Amp”and should comply with current regulations.
-
The earthed outlet must be in close vicinity of the appliance. Never use an extension lead.
-
The supply cable should not make contact with the product’s hot surface.
-
In case of any damage to the supply cable, please call Caple Service. The cable must be replaced
by a qualified installer/electrician)
-
Faulty wiring may damage the appliance. Such damage will not be covered by the warranty.
-
When wiring the terminal box care should be taken to fit and tighten the links on the live and
neutral terminals