background image

ASSEMBLY

 

 

Remove

 

Legs,

 

collar,

 

blanking

 

plate

 

and

 

accessory

 

pack

 

from

 

the

 

stove.

  

The

 

collar

 

can

 

be

 

fitted

 

top

 

or

 

rear.

 

The

 

legs

 

are

 

fitted

 

by

 

screwing

 

the

 

M8

 

studs

 

into

 

the

 

leg

 

positions

 

underneath

 

the

 

stove,

 

locating

 

the

 

legs

 

in

 

position

 

and

 

using

 

the

 

large

 

washers,

 

spring

 

washers

 

and

 

hexagonal

 

nuts

 

to

 

secure

 

them

 

in

 

place.

  

The

 

legs

 

can

 

be

 

fitted

 

at

 

front

 

of

 

ash

 

lip

 

or

 

rearward.

 

To

 

make

 

easier

 

for

 

handling

 

on

 

installation,

 

remove

 

the

 

baffle

 

plate,

 

side

 

bricks,

 

back

 

brick

 

and

 

door.

  

Place

 

in

 

a

 

secure

 

place

 

to

 

avoid

 

damage.

  

Refit

 

after

 

installation.

 

 

INSTALLATION,

 

OPERATION

 

AND

 

MAINTENANCE

 

 

IMPORTANT:

 

THIS

 

APPLIANCE

 

MUST

 

BE

 

INSTALLED

 

BY

 

A

 

COMPETENT

 

PERSON

 

AND

 

MUST

 

COMPLY

 

WITH

 

NATIONAL

 

BUILDING

 

REGULATIONS

 

AND

 

LOCAL

 

BY

LAWS.

  

UNLESS

 

THE

 

INSTALLER

 

IS

 

QUALIFIED

 

TO

 

APPROVE

 

INSTALLATION

 

THEN

 

APPROVAL

 

MUST

 

BE

 

SOUGHT

 

FROM

 

YOUR

 

LOCAL

 

BUILDING

 

CONTROL

 

DEPARTMENT.

  

THE

 

SUPPLIERS

 

ACCEPT

 

NO

 

RESPONSIBILITY

 

IF

 

THE

 

ADVICE

 

IS

 

NOT

 

COMPLIED

 

WITH.

  

THIS

 

APPLIANCE

 

HAS

 

BEEN

 

EXTENSIVELY

 

TESTED

 

FOR

 

SAFETY

 

AND

 

EFFICIENCY,

 

DO

 

NOT

 

ATTEMPT

 

TO

 

MODIFY

 

IT.

  

ALWAYS

 

USE

 

GENUINE

 

REPLACEMENT

 

PARTS

 

AS

 

RECOMMENDED

 

BY

 

YOUR

 

SUPPLIER.

  

FAILURE

 

TO

 

ADHERE

 

TO

 

THIS

 

ADVICE

 

COULD

 

INVALIDATE

 

YOUR

 

GUARANTEE.

 

 

 

INSTALLATION

 

 

Check

 

the

 

chimney

 

is

 

in

 

good

 

condition,

 

dry,

 

free

 

from

 

cracks

 

and

 

obstructions.

 

The

 

diameter

 

of

 

the

 

flue

 

should

 

not

 

be

 

less

 

than

 

150mm

 

and

 

not

 

more

 

that

 

230mm.

  

If

 

any

 

of

 

these

 

requirements

 

are

 

not

 

met,

 

the

 

chimney

 

should

 

be

 

lined

 

by

 

a

 

suitable

 

method.

 

 

The

 

chimney

 

height

 

and

 

the

 

position

 

of

 

the

 

chimney

 

terminal

 

should

 

conform

 

to

 

Building

 

Regulations.

 

 

GENERAL

 

MAINTENANCE

 

 

Baffle

 

Plate

 

 

This

 

should

 

be

 

removed

 

at

 

least

 

once

 

a

 

month

 

to

 

prevent

 

a

 

build

 

up

 

of

 

soot

 

or

 

fly

 

ash

 

which

 

could

 

lead

 

to

 

blocked

 

flue

 

ways

 

and

 

dangerous

 

fume

 

emission.

 

If

 

baffle

 

plate

 

is

 

removed

 

the

 

chimney/flue

 

can

 

be

 

swept

 

through

 

the

 

appliance.

 

 

To

 

avoid

 

a

 

build

 

up

 

of

 

soot

 

on

 

the

 

baffle

 

(the

 

plate

 

inside

 

the

 

stove

 

above

 

the

 

grate)

 

this

 

must

 

be

 

removed

 

and

 

cleaned

 

periodically.

  

This

 

plate

 

locates

 

the

 

back

 

and

 

side

 

firebricks

 

so

 

note

 

its

 

position

 

before

 

removal.

  

To

 

remove,

 

lift

 

plate

 

and

 

remove

 

one

 

side

 

brick,

 

this

 

will

 

allow

 

plate

 

to

 

drop

 

and

 

aid

 

removal.

  

To

 

replace,

 

position

 

baffle

 

plate

 

on

 

back

 

and

 

side

 

brick,

 

lift

 

plate

 

and

 

replace

 

remaining

 

brick,

 

make

 

sure

 

it

 

is

 

located

 

in

 

position.

 

This

 

must

 

be

 

done

 

when

 

the

 

stove

 

is

 

cold.

 

 

Baffle

 

Plate

 

Removal

 

and

 

Replacement

 

 

Note

 

position

 

before

 

removal.

 

To

 

remove

 

baffle

 

plate,

 

lift

 

up

 

and

 

remove

 

one

 

side

 

brick

 

left

 

or

 

right.

 

The

 

baffle

 

plate

 

can

 

now

 

be

 

manipulated

 

out

 

of

 

the

 

stove

 

door

 

opening.

 

Remove

 

the

 

remaining

 

back

 

and

 

side

 

brick—as

 

the

 

bricks

 

are

 

free

standing

 

no

 

damage

 

can

 

now

 

occur

 

due

 

to

 

bricks

 

falling

 

over.

 

To

 

replace,

 

place

 

rear

 

brick

 

in

 

position

 

and

 

one

 

side

 

brick.

 

Manipulate

 

baffle

 

into

 

position

 

and

 

fit

 

remaining

 

side

 

brick.

 

Make

 

sure

 

all

 

parts

 

are

 

located.

 

 

Grate

 

Removal

 

Sirius

 

405

 

 

The

 

Sirius

 

405

 

has

 

a

 

single

 

rotating

 

grate

 

operated

 

by

 

an

 

attached

 

riddling

 

rod.

 

To

 

remove,

 

unscrew

 

control

 

knob

 

and

 

rotate

 

grate

 

out

 

of

 

its

 

guide

 

hole.

 

The

 

centre

 

grate

 

can

 

now

 

be

 

removed.

 

To

 

replace

 

grate,

 

reverse

 

this

 

procedure.

 

Note

 

position

 

of

 

grate

 

riddling

 

rod

 

as

 

it

 

connects

 

to

 

grate.

 

The

 

hook

 

on

 

the

 

end

 

of

 

the

 

rod

 

passes

 

under

 

and

 

up

 

through

 

the

 

arm

 

hole

 

on

 

the

 

grate.

 

If

 

the

 

removal

 

of

 

the

 

outer

 

grate

 

is

 

required

 

then

 

the

 

baffle

 

plate,

 

rear

 

and

 

side

 

bricks

 

will

 

require

 

removal.

 

The

 

outer

 

grate

 

will

 

then

 

lift

 

out

 

off

 

its

 

stops.

 

 

 
 
 
 

 

 

3

 

16

Summary of Contents for Sirius 405

Page 1: ...NT USE Dimensions may vary slightly the manufacturers reserve the right to adjust them without notice Outputs stated are under ideal test conditions Variations may occur due to installation atmospheri...

Page 2: ...INSTALLATION AND OPERATING INSTRUCTIONS FOR THE SIRIUS FAMILY OF CAST IRON MULTI FUEL STOVES PLEASE LEAVE THIS BOOKLET WITH THE HOUSEHOLDER The Sirius Stoves operate at very high temperatures All per...

Page 3: ...nry fall dust build up or furniture blocking vents C Poor quality fuel Only burn dry seasoned timber soft woods have a lower heat output than hard woods per hour Solid fuels vary in heat value check w...

Page 4: ...t Dublin Tel 01 801 5959 4 CHIMNEY FIRE Identified by loud roaring sounds dense smoke and sparks exiting chimney Shut down air supply to stove by closing air vents close stove door fully call Fire Bri...

Page 5: ...ould be removed at least once a month to prevent a build up of soot or fly ash which could lead to blocked flue ways and dangerous fume emission If baffle plate is removed the chimney flue can be swep...

Page 6: ...034 36 and 37 Stove Body Rear Right Left Panel 4 FFX003 FFX8003 FFX12003 Stove Top 7 FFX002 FFX8002 FFX12002 Stove Base 8 FFX005 N A FFX12005 Grate Support 9 FFX006 N A FFX12005B Grate 10 FFX007 FFX80...

Page 7: ...e is in an over fire situation and the controls should be adjusted accordingly Never leave the stove unattended for long periods without adjusting the controls to a safe setting careful air supply con...

Page 8: ...st be done when the appliance is cold Any structural repairs i e panel collar replacement or stove pipe must be carried out by a suitably qualified engineer A flue draught of minimum 12 Pascals and a...

Page 9: ...for refuelling Not only is it unsafe to operate with the door open but the appliance efficiency will be significantly reduced Lighting The Stove It is essential that you have two or three small fires...

Page 10: ...fuel Set air controls as required Solid Fuels We recommend the majority of approved manufactured smokeless fuels Household coal which is smokey fuel can also be used but note that different types will...

Page 11: ...rius 405 has no ventilation requirement Considerations and provisions must be made for any other appliances requiring ventilation An extractor fan must not be used in the same location as the applianc...

Page 12: ...o remove surplus ash from the grate occasionally Burn only kiln dried or well seasoned wood which should have been cut split and stacked under cover for at least 36 months with free air movement aroun...

Reviews: