background image

 

 

 

 

 

 

Capital

 

Fireplace

 

Limited

 

Unit

 

12

17,

 

Henlow

 

Trading

 

Estate,

 

Henlow

 

Camp,

 

Herts.

 

SG16

 

6DS

 

01462

 

813138

 

www.capitalfireplaces.co.uk

 

 

 
 

Sirius

 

405,

 

545

 

and

 

645

 

 

APPROVED

 ‐ 

CONFORMING

 

TO

 

EN13240:2001

 

 

 

 

INSTALLATION

 

AND

 

OPERATING

 

INSTRUCTIONS

 

FOR

 

THE

 

SIRIUS

 

FAMILY

 

OF

 

CAST

 

IRON

 

MULTI

FUEL

 

STOVES

 

 

PLEASE

 

LEAVE

 

THIS

 

BOOKLET

 

WITH

 

THE

 

HOUSEHOLDER

 

 

The

 

Sirius

 

Stoves

 

operate

 

at

 

very

 

high

 

temperatures.

 

All

 

persons

 

including

 

children

 

and

 

the

 

infirm

 

should

 

be

 

warned

 

of

 

this

 

and

 

not

 

allowed

 

to

 

touch

 

any

 

surfaces

 

whilst

 

in

 

use.

  

The

 

operator

 

must

 

use

 

the

 

tools

 

provided.

 

The

 

glove

 

provided

 

is

 

a

 

tool.

 

 
 

Summary of Contents for Sirius 405

Page 1: ...NT USE Dimensions may vary slightly the manufacturers reserve the right to adjust them without notice Outputs stated are under ideal test conditions Variations may occur due to installation atmospheri...

Page 2: ...INSTALLATION AND OPERATING INSTRUCTIONS FOR THE SIRIUS FAMILY OF CAST IRON MULTI FUEL STOVES PLEASE LEAVE THIS BOOKLET WITH THE HOUSEHOLDER The Sirius Stoves operate at very high temperatures All per...

Page 3: ...nry fall dust build up or furniture blocking vents C Poor quality fuel Only burn dry seasoned timber soft woods have a lower heat output than hard woods per hour Solid fuels vary in heat value check w...

Page 4: ...t Dublin Tel 01 801 5959 4 CHIMNEY FIRE Identified by loud roaring sounds dense smoke and sparks exiting chimney Shut down air supply to stove by closing air vents close stove door fully call Fire Bri...

Page 5: ...ould be removed at least once a month to prevent a build up of soot or fly ash which could lead to blocked flue ways and dangerous fume emission If baffle plate is removed the chimney flue can be swep...

Page 6: ...034 36 and 37 Stove Body Rear Right Left Panel 4 FFX003 FFX8003 FFX12003 Stove Top 7 FFX002 FFX8002 FFX12002 Stove Base 8 FFX005 N A FFX12005 Grate Support 9 FFX006 N A FFX12005B Grate 10 FFX007 FFX80...

Page 7: ...e is in an over fire situation and the controls should be adjusted accordingly Never leave the stove unattended for long periods without adjusting the controls to a safe setting careful air supply con...

Page 8: ...st be done when the appliance is cold Any structural repairs i e panel collar replacement or stove pipe must be carried out by a suitably qualified engineer A flue draught of minimum 12 Pascals and a...

Page 9: ...for refuelling Not only is it unsafe to operate with the door open but the appliance efficiency will be significantly reduced Lighting The Stove It is essential that you have two or three small fires...

Page 10: ...fuel Set air controls as required Solid Fuels We recommend the majority of approved manufactured smokeless fuels Household coal which is smokey fuel can also be used but note that different types will...

Page 11: ...rius 405 has no ventilation requirement Considerations and provisions must be made for any other appliances requiring ventilation An extractor fan must not be used in the same location as the applianc...

Page 12: ...o remove surplus ash from the grate occasionally Burn only kiln dried or well seasoned wood which should have been cut split and stacked under cover for at least 36 months with free air movement aroun...