7

 

VENTILATION REQUIREMENTS 

 
STEP 2: 
 

A suitable exhaust hood must be installed above the wok. The following chart indicates the Minimum 
blower capacity recommended for hood ventilation. 
 
                                                    
    
  
 
                                                 
                                      

   

     

CAUTION:

 

   
 

Ventilation hoods and blowers are designed for use with single wall 
Ducting,

 however, some local building codes or inspectors may require 

double wall ducting. Consult local building codes and/or local agencies, 
before starting to ensure that the hood and duct installation will meet 
local requirements. 

 
 
 

A variable speed Hood blower can reduce noise and loss of air conditioned household air when 
maximum ventilation is not required. Normally, the maximum blower speed is only required when the 
wok burner is in operation. For best smoke elimination, the lower edge of the hood should be installed 
a minimum of 36” above the wok cooking surface, (step 3 pg. 8). If the hood contains any combustible 
materials (i.e. wood covering) it must be a minimum of 36” above the cooking surface. Due to a high 
volume of ventilation air, a source of outside replacement air is recommended. This is particularly 
important for tightly sealed and insulated homes. A reputable heating and ventilating contractor 
should be consulted. 
 
 
 

 

VENTILATION STANDARD 

COUNTER 

ISLAND 

UNIT INSTALLATION 

INSTALLATION 

  

RECOMMENDATIONS 

RECOMMENDATIONS 

HOOD 

24" Deep x Unit Width 

30" Deep x 36" at Bottom 

24” WOK 

BLOWER 

1200 CFM 

1200 CFM 

Summary of Contents for Performance PSQ24WK

Page 1: ...GRT24WK AND PSQ24WK 24 WOK MODEL INSTALLATION MANUAL...

Page 2: ...ons arise from time to time so we want to make it easy for you to find the answers That s why we pride ourselves on superior customer service and work harder to respond to your needs quickly and effic...

Page 3: ...N 4 MODEL 5 UNPACKING HANDLING 6 VENTILATION REQUIREMENTS 7 CABINET PREPARATION 8 13 BACKGUARD INSTALLATION 14 ELECTRICAL GAS CONNECTIONS 15 GAS REQUIREMENTS 16 TEST AND ADJUSTMENTS 17 INSTALLER FINAL...

Page 4: ...with all applicable codes In the absence of local codes the wok should be installed in accordance with the National Fuel Gas Code ANSI Z223 1 1988 and National Electrical Code ANSI NFPA 70 1990 Verify...

Page 5: ...the manufacturer 5 Finding a leak is not a do it yourself procedure Some leaks can only be found with the burner control in the on position and this must be done by a qualified technician 6 The LP sup...

Page 6: ...5 MODEL 24 PS Wok Outdoor and 24 GRT Wok Indoor...

Page 7: ...k to avoid personal injury or damage to the unit ANCHORING THE WOK The woks have a shipping weight of approximately 90 pounds Remove all packing materials and the outer carton from the shipping base T...

Page 8: ...maximum ventilation is not required Normally the maximum blower speed is only required when the wok burner is in operation For best smoke elimination the lower edge of the hood should be installed a m...

Page 9: ...es The countertop must be strong enough to support this heavy wok It may be necessary to add a supporting cleat along each side or another form of support such as a 2 x 4 corner brace on each side or...

Page 10: ...iagrams Standard counter top installation see Fig 5A Deep counter or island installation see Fig 5B NOTE If the deck is used the sides or bottom of the cutout may be solid combustible or non combustib...

Page 11: ...10 CABINET PREPARATION...

Page 12: ...11 CABINET PREPARATION INDOOR INSTALLATION...

Page 13: ...12 CABINET PREPARATION OUTDOOR INSTALLATION...

Page 14: ...13 CABINET PREPARATION...

Page 15: ...behind the wok Specific instructions for installation of the high or low backguards can be found packaged with the backguard The back guard must be installed when there is less than a 12 clearance be...

Page 16: ...d obligation of the installer to have the existing receptacle changed to a properly grounded and polarized receptacle in accordance with all applicable local codes and ordinances by a qualified electr...

Page 17: ...of the regulator to the exposed end of the nipple connect the flex line from the gas supply to the inlet side of the regulator Apply Teflon tape to threads NOTE The arrow on the regulator indicating...

Page 18: ...by wiping with a damp soapy cloth Any mild glass cleaner will remove fingerprints and smears Do not use steel wool as it will scratch this surface Small scratches may be removed by lightly sanding wit...

Page 19: ...mpere over current protection is provided for service cord connection Adequate ground connection GAS SUPPLY Connection 1 2 NPT with a minimum 5 8 diameter metal flex line Site gas supply is compatible...

Page 20: ...please have the following information available Model Number Serial Number Date of installation A brief description of the problem Your satisfaction is our top priority If the problem persists or is n...

Page 21: ...ructions or local codes where the appliance has been tempered with or altered in any way or which in our judgment has been subjected to misuse negligence or accident Implied warranty shall not extend...

Page 22: ...21 NOTES...

Page 23: ...GRT24WK AND PSQ24WK 24 WOK MODEL INSTALLATION MANUAL...

Reviews: