INSTALLER FINAL CHECKLIST
GENERAL
□
Placement of unit.
□
Specified clearance maintained to cabinet surfaces.
□
Unit level – front to back, side to side.
□
All packaging material and tie straps removed, drip pans clean and empty.
□
Backguard attached if there is less than 12” clearance above the cooking surface to combustibles
behind unit.
ELECTRICAL
□
Receptacle with 15 ampere over-current protection is provided for service cord connection.
□
Adequate ground connection.
GAS SUPPLY
□
Connection: 1/2 NPT with a minimum 5/8” diameter metal flex line.
□
Site gas supply is compatible with wok model, & sufficient pressure is available
(see gas requirements pg. 12)
□
Manual gas shut-off valve installed in accessible location.
□
Unit tested and free of gas leaks.
OPERATION
□
All internal packing materials removed.
□
Bezel centered on burner knob and knob turn freely.
□
Burners lights satisfactorily.
□
Burner grate correctly positioned, level, and do not rock.