BURNER ADJUSTMENTS
BURNER AIR ADJUSTMENT:
To Adjust Tube Burner Flames:
1.
Be careful as the burner may be very hot!
2.
If the flame is yellow, indicating insufficient air, adjust the air shutter counter clockwise to allow more air to
the burner.
3.
If the flame is noisy and tends to lift away from the burner, indicating too much air, turn the air shutter
clockwise
4.
Once adjusted, turn the burner off, lock the air shutter in position and reverse steps to reassemble.