background image

Manway Davit Mount System

Model#: 8520267 and 8560267

ISO 9001

REGISTERED

Capital Safety USA: 800.328.6146 • Canada: 800.387.7484 • Asia: + 65 6558 7758 •

Australia/New Zealand: 800 245 002 • Europe, Middle East, Africa: +33 (0) 497 10 00 10 •

Northern Europe: +44 (0) 1928 571324

www.capitalsafety.com • [email protected]

FlexiGuard

 

CUSTOM FALL 

PROTECTION SOLUTIONS

TM

Figure 1 - PARTS DIAGRAM

1. TRI-SCREW
2. TRI-SCREW LANYARD
3. LEG TUBE SLIDER
4. MAIN BODY WELDMENT
5. WARNING LABEL
6. PROOF LOAD LABEL
8.1/2” TYPE A WASHER
9. THRUST BEARING DISC
10. PVC LINER SLEEVE 
11. WORKING LOAD LABEL
13. LEG SLIDER STOP
14. LEG TUBE
15. 3/8” TYPE A WASHER
16. 3/8-16 X 3.25 GR.5 BOLT
17. 1/2-13 X 3.25 GR.5 BOLT
18. 1/2-13 NYLON LOCK NUT
19.  PRODUCT ID LABEL
20. 3/8-16 NYLON LOCK NUT

REAR 
MOUNTING 
FLANGE

LEG SLIDER 
MOUNTING 
HOLE

5000lb 
ANCHOR
POINT

PAGE 3

Summary of Contents for DBI SALA 8520267

Page 1: ...A Capital Safety Company USER INSTRUCTIONS 8520267 MANWAY DAVIT MOUNT SYSTEM Form 5903030 Rev A FlexiGuard CUSTOM FALL PROTECTION SOLUTIONS TM ...

Page 2: ...ipe ASTM D 1785 Thrust Bearing Material High Density Polyethene Finish Steel Sleeves Zinc Plate Plating Specification ASTM Designation B633 TYPE II CLASS 1 Hardware Specification Gr 5 Gr 8 Zinc Plated Mounting Requirements Surfaces selected to mount the system must be certified by a qualified person to be capable of supporting a minimum 33 000 in lb 3 730 n m and 5000 lb 2268 kg vertical load Moun...

Page 3: ...iGuard CUSTOM FALL PROTECTION SOLUTIONS TM Figure 1 PARTS DIAGRAM 1 TRI SCREW 2 TRI SCREW LANYARD 3 LEG TUBE SLIDER 4 MAIN BODY WELDMENT 5 WARNING LABEL 6 PROOF LOAD LABEL 8 1 2 TYPE A WASHER 9 THRUST BEARING DISC 10 PVC LINER SLEEVE 11 WORKING LOAD LABEL 13 LEG SLIDER STOP 14 LEG TUBE 15 3 8 TYPE A WASHER 16 3 8 16 X 3 25 GR 5 BOLT 17 1 2 13 X 3 25 GR 5 BOLT 18 1 2 13 NYLON LOCK NUT 19 PRODUCT ID...

Page 4: ...s must be installed maintained and used according to the manufacturer s instructions THE MOUNTING STRUCTURE MUST MEET THE REQUIREMENTS STATED ON PAGE 2 OF THIS DOCUMENT This davit base is to be used only with the following DBI Sala Capital Safety davit offsets 6 12 18 This system is to be used with a max of one Capital Safety Mast Extension having a length of up to 24 610 mm Multiple extensions MU...

Page 5: ... person other than the user Record results of inspection in the inspection and maintenance log provided IMPORTANT Extreme working conditions harsh environments prolonged use may require increasing the frequency of inspections WARNING If the system has been subjected to fall arrest forces it must be immediately removed from service and inspected If the system fails inspection remove from service an...

Page 6: ...ECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By PAGE 6 ...

Page 7: ...ECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By PAGE 7 ...

Page 8: ...SCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND SHALL NOT BE LIABLE FOR INCIDENTAL PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY NATURE INCLUDING WITHOUT LIMITATION LOST PROFITS REVENUES OR PRODUCTIVITY OR FOR BODILY INJURY OR DEATH OR LOSS OR DAMAGE TO PROPERTY UNDER ANY THEORY OF LIABILITY INCLUDING WITHOUT LIMITATION CONTRACT WARRANTY STRICT LIABILITY TORT I...

Reviews: