Manway Davit Mount System

Model#: 8520267 & 8560267

Inspection:

  

Before Every Use:

  *All fasteners must be tight, secure and not damaged.
  *Ensure system is free of cracks, dents, distortion, or any other damage.
  *Inspect for corrosion or rust.
  *All labels must be present and fully legible.
  *Record results of inspection in the inspection and maintenance log provided.
  *If inspection reveals an unsafe or defective condition, remove the system from service and 
   destroy, or contact Capital Safety Group for repair or replacement.

  Monthly:

  *A formal inspection of the system should be done by a competent person other than the user.  
   Record results of inspection in the inspection and maintenance log provided.

IMPORTANT: 

Extreme working conditions (harsh environments, prolonged use) may require increasing 

the frequency of inspections.

WARNING: 

If the system has been subjected to fall arrest forces, it must be immediately removed from 

service and inspected. If the system fails inspection, remove from service and destroy, or contact Capital 
Safety Group for repair or replacement.

SERIAL NO.

MFRD

(Y/M)

:          

LOT NO.: 

       

MODEL NO.:

         

LENGTH

(FT)

:

www.capitalsafety.com

(800) 328-6146

9504547

Labels:

9504547

FlexiGuard

 

CUSTOM FALL 

PROTECTION SOLUTIONS

TM

This component is rated for a working
load of 450 lb. (205 kg). Retractable
devices or shock absorbers must have a
MAXIMUM ARRESTING FORCE (M.A.F.)
RATING OF 900 lb. (4kN) OR LESS.
System rating is that of the lowest rated
system component.

WARNING

Pt# 13219

8513219

This base is to be used
only with the following
offsets:

Pt# 8514755

6” 12” 18” 24” 30” 36” 48”

WARNING

8514755

8513424

8515272

(CE certified models only)

PAGE 5

Summary of Contents for DBI SALA 8520267

Page 1: ...A Capital Safety Company USER INSTRUCTIONS 8520267 MANWAY DAVIT MOUNT SYSTEM Form 5903030 Rev A FlexiGuard CUSTOM FALL PROTECTION SOLUTIONS TM ...

Page 2: ...ipe ASTM D 1785 Thrust Bearing Material High Density Polyethene Finish Steel Sleeves Zinc Plate Plating Specification ASTM Designation B633 TYPE II CLASS 1 Hardware Specification Gr 5 Gr 8 Zinc Plated Mounting Requirements Surfaces selected to mount the system must be certified by a qualified person to be capable of supporting a minimum 33 000 in lb 3 730 n m and 5000 lb 2268 kg vertical load Moun...

Page 3: ...iGuard CUSTOM FALL PROTECTION SOLUTIONS TM Figure 1 PARTS DIAGRAM 1 TRI SCREW 2 TRI SCREW LANYARD 3 LEG TUBE SLIDER 4 MAIN BODY WELDMENT 5 WARNING LABEL 6 PROOF LOAD LABEL 8 1 2 TYPE A WASHER 9 THRUST BEARING DISC 10 PVC LINER SLEEVE 11 WORKING LOAD LABEL 13 LEG SLIDER STOP 14 LEG TUBE 15 3 8 TYPE A WASHER 16 3 8 16 X 3 25 GR 5 BOLT 17 1 2 13 X 3 25 GR 5 BOLT 18 1 2 13 NYLON LOCK NUT 19 PRODUCT ID...

Page 4: ...s must be installed maintained and used according to the manufacturer s instructions THE MOUNTING STRUCTURE MUST MEET THE REQUIREMENTS STATED ON PAGE 2 OF THIS DOCUMENT This davit base is to be used only with the following DBI Sala Capital Safety davit offsets 6 12 18 This system is to be used with a max of one Capital Safety Mast Extension having a length of up to 24 610 mm Multiple extensions MU...

Page 5: ... person other than the user Record results of inspection in the inspection and maintenance log provided IMPORTANT Extreme working conditions harsh environments prolonged use may require increasing the frequency of inspections WARNING If the system has been subjected to fall arrest forces it must be immediately removed from service and inspected If the system fails inspection remove from service an...

Page 6: ...ECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By PAGE 6 ...

Page 7: ...ECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By PAGE 7 ...

Page 8: ...SCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND SHALL NOT BE LIABLE FOR INCIDENTAL PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY NATURE INCLUDING WITHOUT LIMITATION LOST PROFITS REVENUES OR PRODUCTIVITY OR FOR BODILY INJURY OR DEATH OR LOSS OR DAMAGE TO PROPERTY UNDER ANY THEORY OF LIABILITY INCLUDING WITHOUT LIMITATION CONTRACT WARRANTY STRICT LIABILITY TORT I...

Reviews: