Introduction 

The Alarm is a Z-Wave enabled device which is fully compatible with any Z-Wave enabled  

network. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless  

of the manufacture, and ours can also be used in other manufacture’s networks. This device can 

control our modules via controller settings. Inclusion of this alarm on other manufacture’s   

Wireless Controller menu allows remote turn-on of connected modules when the detector is  

triggered.  After  this  product  included  into  the  network,  when  the  associated  device  (such  as: 

sensor) is triggered, the alarm can send out alarm after receiving the wireless message. The alarm 

is  a  combination  of  alarm  and  flash,  the  alarm  volume  can  reach  100  db  and  90  db.  When  the 

alarm  receiving  a  wireless  (RF)  directive,  may  be  lead  to  two  kinds  of  results:  it  is  to  start  the 

alarm and flash or it is to close the alarm and flash. 

CT-SMZW2008-ES 

Alarm 

 

Summary of Contents for CT-SMZW2008-ES

Page 1: ...settings Inclusion of this alarm on other manufacture s Wireless Controller menu allows remote turn on of connected modules when the detector is triggered After this product included into the network when the associated device such as sensor is triggered the alarm can send out alarm after receiving the wireless message The alarm is a combination of alarm and flash the alarm volume can reach 100 db...

Page 2: ... volume can reach 100 db and 90 db Specifications Radio protocol Z Wave Operation Frequency 868 42MHz 908 42 MHz SP814 2 921 42 MHz SP814 9 Power supply DC6V 600mA 1 5V LR14 x 4 Battery life 1 year RF range 25m in an open area of the wireless controller and the latest line of sight between Z Wave receiving module Alarm volume 100 db and 90 db Operation As shown below respectively alarm front side ...

Page 3: ...ssed 4 When prompt a message Request Access Success please go to the device list interface and refresh the device list the device will be displayed Z WAVE NETWORK EXCLUSION 1 Make sure the device is connected to the power supply 2 Remove the device on the APP then click finish 3 Pressing link key 3 times within 1 5 second The green LED lights up and sends out beep sound when link key is pressed 4 ...

Page 4: ...nds out beep sound when link key is pressed 3 Within 1 second press and hold the link key about 5 seconds until the LED light turns off A long beep is sounded for 5 seconds and the LED light turns off 4 IDs are excluded and all of preset value will be reset to factory default LED 2 second on 2 second off Beep sound every 10 seconds 0 1 seconds each ring Installation Instructions It s recommended t...

Page 5: ...th cable wire slot which can connect with the transformer connection wire If you use the transformer please insert the transformer coupling into the DC hole then connect the wire with wire slot Fig 4 5 Fig 4 Fig 5 3 Using the back cover as the example identified three screw holes on the wall Use the attached plastic gecko and screws fixed the back cover on the wall Fig 6 Fig 6 4 Put the alarm main...

Page 6: ...er is designed to start the alarm to notify users and deter vandals when alarm is force forcibly removed When the switch is pressed for more than 3 seconds later tamper function will start If you switch off again at this time it is equal to remove it from the wall after installation then an alarm is raised and flash and the alarm will last for 3 minutes Safety Notice Don t make the device directly...

Page 7: ...d by the detector is consistent with actual ambient illumination Do not locate the detector in shadowy place Where possible mount the detector so that the logical path of an intruder would cut across the fan pattern rather than directly towards the detector In order to obtain the best results please put the detector directly facing the entrance ...