![CanyCom CMX 252 Operator'S Manual Download Page 82](http://html.mh-extra.com/html/canycom/cmx-252/cmx-252_operators-manual_493776082.webp)
-73-
Maintenance
5
5332M-0509-020E
Main Fuse
Fuse Case
Cap
Lights Fuse
1. Open engine hood.
2. Push reset button to reset circuit breaker.
3. Close engine hood.
Fuse Case
5341M-0509-030E
Resetting Circuit Breaker
1. Open engine hood.
2. Open fuse case cap. Remove fuse and
visually inspect. If it is blown, replace it with
new one of the same rating.
3. Install fuse.
4. Install fuse case cap.
5. Close engine hood.
5341M-0509-020E
Reset Button
• Circuit breaker protects mower deck slide
mechanism. Check this breaker when slide
mechanism does not work.
NOTE
Replacing Main/Light Fuse
1. Lift up seat.
2. Open fuse case cap. Remove fuse and
visually inspect. If it is blown, replace it with
new one of the same rating.
3. Install fuse.
4. Install fuse case cap.
5. Lower seat.
Replacing Mower Deck Lift Fuse
• The fuse that protects mower deck lift
mechanism is located under the seat. Check
this fuse when lift mechanism does not
work.
NOTE