-49-
Maintenance
5
When this machine is shipped from the factory,
it is filled with a mixture of 40% antifreeze and
60% water. To prevent coolant from freezing, use
a mixture of water and antifreeze determined by
the minimum temperature in the operation area
using the table on the left.
Antifreeze Mixture (Reference)
Ambient
Temperature
Antifreeze
Mixture
-10 °C (14 °F)
30%
-15 °C (5 °F)
35%
-20 °C (-4 °F)
40%
-25 °C (-13 °F)
45%
* The value for the ambient temperature
is 5°C lower than the actual minimum
temperature.
• Antifreeze to use: Long Life Coolant (LLC).
• Use pure water to make antifreeze mixture.
NOTE
4. Remove drain plug to drain coolant.
5. Wash inside radiator with running water.
6. Replace drain plug.
Drain Plug
5116M-0505-100E
Filler
5116M-0505-110E
Reservoir Tank
5116M-0505-070E
7. Fill coolant into radiator up to filler.
8. Change coolant in reservoir tank.
9. Run engine for 5 minutes to bleed air.
10. Allow engine to cool and open radiator filler
cap and top up with coolant.
11. Replace radiator cap.
12. Close top cover.