8
ENGLISH
10.
VESA/60
1280×1024 64.0
60
Non-interlaced
11.
VESA/75
1280×1024 80.0
75
Non-interlaced
12.
--
1360X768 47.7 60
Non-interlaced
13.
--
1680X1050 65.3
60
Non-interlaced
14.
--
1920X1080 67.5
60
Non-interlaced
7. Signal Connector Pin-outs
To connect VGA, 8514A or IBM-compatible graphics adapters, use a 15 pin mini D-type male connector.
8. Power Saving Feature
When the power saving active them the power indicator LED will be from Green Light to Amber, And
power saving feature complies with these VESA power saving modes:
Mode
H. Sync.
V. Sync.
LED
Power
Consumption
Normal On
On Green <50W
Stand-by Off
On Amber
<
3W
Suspend On
Off Amber
<
3W
Off Off Off
Amber
<
3W
The monitor uses the H. Sync and V. Sync signals to determine the operation mode to enter.
The monitor power-saving feature automatically turns off H. Sync and V. Sync if there is no input from
the system for a certain period of time. To use this feature, you need a green PC that is compliant with
the VESA power saving feature or a software utility to detect system input such as keyboard or mouse.
Time Settings
Time settings are adjusted from the system unit by software. To fulfill the requirements in the NUTEK
specification 803299/94 the total time from indicated inactivity to Power Saving position A2 (VESA OFF)
must not be set more than 70 minutes. We recommend you switch off the monitor when you do not
intend to use it for awhile.
15-pin Mini D-type Male Connector
Pin Assignment
1 Red Video
6
Red Ground
11 Ground
2 Green Video
7
Green Ground
12 Serial Data/I/O
3 Blue Video
8
Blue Ground
13 H. Sync
4 Ground
9
VGA +5V
14 V. Sync
5 No Connection
10 Sync Ground
15 Serial Clock Input